============================================================================= SHIFTS, version 4.1 [X.-P. Xu and D.A. Case, Mar. 2002] ============================================================================= shifts will be computed for atoms matching ::H* found 23 rings ring int. center anis. iso. PHE 6 1.000 12.856 -13.456 17.812 -99.200 -91.000 PHE 18 1.000 10.483 -15.434 -0.497 -99.200 -91.000 PHE 24 1.000 1.625 -15.178 4.604 -99.200 -91.000 PHE 26 1.000 -1.685 -14.458 0.815 -99.200 -91.000 TYR 37 0.840 -5.491 0.352 -3.383 -99.200 -91.000 TYR 44 0.840 -0.535 16.488 5.986 -99.200 -91.000 PHE 46 1.000 -1.643 10.946 4.326 -99.200 -91.000 HIS 47 0.900 -3.809 10.584 -4.238 -99.200 -91.000 TRP 76 1.040 5.899 17.886 2.085 -99.200 -91.000 TRP6 76 1.020 3.766 18.679 2.654 -99.200 -91.000 TYR 87 0.840 3.477 -13.031 7.563 -99.200 -91.000 TYR 88 0.840 6.863 -7.521 14.148 -99.200 -91.000 TYR 96 0.840 5.684 2.270 -1.194 -99.200 -91.000 TYR 102 0.840 9.528 13.806 7.998 -99.200 -91.000 PHE 116 1.000 -0.467 -4.527 3.082 -99.200 -91.000 PHE 126 1.000 -9.946 3.827 1.401 -99.200 -91.000 TYR 129 0.840 -2.436 9.980 8.814 -99.200 -91.000 TYR 137 0.840 3.861 10.795 7.156 -99.200 -91.000 PHE 139 1.000 -0.851 6.101 5.316 -99.200 -91.000 TRP 141 1.040 -4.548 -2.375 2.371 -99.200 -91.000 TRP6 141 1.020 -3.455 -1.075 0.728 -99.200 -91.000 TYR 142 0.840 -8.837 -2.430 9.321 -99.200 -91.000 TYR 145 0.840 -5.915 -9.987 -2.250 -99.200 -91.000 ============================================================================= Atom RingCur El P_anis Const RC pred Obs ============================================================================= 2kvaA1 GLU 578 HA 0.03 -0.14 0.26 -0.75 4.29 3.68 2kvaA1 GLU 578 HB2 0.02 0.05 0.06 -0.04 2.09 2.17 2kvaA1 GLU 578 HB3 0.01 -0.11 -0.01 -0.04 1.99 1.84 2kvaA1 GLU 578 HG2 0.02 0.03 0.02 -0.04 2.34 2.38 2kvaA1 GLU 578 HG3 0.03 -0.03 0.05 -0.04 2.34 2.35 2kvaA1 ALA 579 H 0.02 -0.01 0.16 -0.55 8.40 8.02 2kvaA1 ALA 579 HA 0.01 0.32 0.92 -0.75 4.34 4.84 2kvaA1 ALA 579 HB3 0.02 -0.00 0.06 -0.04 1.41 1.44 2kvaA1 GLU 580 H 0.01 -0.02 0.07 -0.55 8.60 8.10 2kvaA1 GLU 580 HA -0.01 0.04 0.28 -0.75 4.29 3.85 2kvaA1 GLU 580 HB2 -0.00 0.23 -0.06 -0.04 2.09 2.22 2kvaA1 GLU 580 HB3 -0.01 0.01 0.18 -0.04 1.99 2.13 2kvaA1 GLU 580 HG2 -0.01 -0.01 -0.03 -0.04 2.34 2.25 2kvaA1 GLU 580 HG3 0.00 0.02 -0.34 -0.04 2.34 1.98 2kvaA1 ALA 581 H 0.01 -0.11 -0.31 -0.55 8.40 7.44 2kvaA1 ALA 581 HA 0.02 0.27 0.81 -0.75 4.34 4.68 2kvaA1 ALA 581 HB3 0.02 0.02 -0.04 -0.04 1.41 1.37 2kvaA1 GLU 582 H 0.01 -0.20 -0.02 -0.55 8.60 7.85 2kvaA1 GLU 582 HA 0.05 0.01 0.37 -0.75 4.29 3.97 2kvaA1 GLU 582 HB2 -0.02 0.01 0.05 -0.04 2.09 2.10 2kvaA1 GLU 582 HB3 0.01 0.08 -0.03 -0.04 1.99 2.01 2kvaA1 GLU 582 HG2 0.02 0.08 0.01 -0.04 2.34 2.42 2kvaA1 GLU 582 HG3 0.03 0.09 0.03 -0.04 2.34 2.44 2kvaA1 PHE 583 H 0.17 0.06 0.20 -0.55 8.34 8.21 2kvaA1 PHE 583 HA -0.04 0.10 0.43 -0.75 4.62 4.36 2kvaA1 PHE 583 HB2 -0.01 0.06 0.12 -0.04 3.15 3.28 2kvaA1 PHE 583 HB3 -0.02 -0.07 0.08 -0.04 3.06 3.01 2kvaA1 PHE 583 HD2 -0.01 -0.04 -0.15 -0.04 7.28 7.04 2kvaA1 PHE 583 HE2 0.01 -0.02 -0.03 -0.04 7.38 7.30 2kvaA1 PHE 583 HZ 0.01 -0.01 -0.01 -0.04 7.32 7.27 2kvaA1 LEU 584 H -0.67 0.15 0.12 -0.55 8.37 7.43 2kvaA1 LEU 584 HA -0.41 0.04 0.61 -0.75 4.35 3.85 2kvaA1 LEU 584 HB2 -0.61 0.02 0.04 -0.04 1.64 1.05 2kvaA1 LEU 584 HB3 -0.39 0.05 0.12 -0.04 1.64 1.39 2kvaA1 LEU 584 HG -0.38 -0.01 0.13 -0.04 1.64 1.34 2kvaA1 LEU 584 HD13 -0.12 0.00 0.02 -0.04 0.93 0.79 2kvaA1 LEU 584 HD23 -0.68 0.01 0.07 -0.04 0.89 0.26 2kvaA1 SER 585 H -0.18 0.24 0.32 -0.55 8.46 8.29 2kvaA1 SER 585 HA 0.09 0.23 0.91 -0.75 4.49 4.96 2kvaA1 SER 585 HB2 0.13 -0.01 0.02 -0.04 3.95 4.05 2kvaA1 SER 585 HB3 0.33 0.03 -0.13 -0.04 3.93 4.11 2kvaA1 ARG 586 H 0.13 0.22 0.12 -0.55 8.46 8.37 2kvaA1 ARG 586 HA 0.13 0.45 1.18 -0.75 4.34 5.34 2kvaA1 ARG 586 HB2 0.22 0.00 -0.09 -0.04 1.90 1.99 2kvaA1 ARG 586 HB3 0.07 -0.01 0.12 -0.04 1.80 1.94 2kvaA1 ARG 586 HG2 0.03 0.00 -0.33 -0.04 1.67 1.33 2kvaA1 ARG 586 HG3 0.07 -0.01 -0.26 -0.04 1.67 1.43 2kvaA1 ARG 586 HD2 -0.04 0.01 -0.16 -0.04 3.22 2.98 2kvaA1 ARG 586 HD3 -0.13 0.00 -0.12 -0.04 3.22 2.93 2kvaA1 THR 587 H 0.09 0.71 0.32 -0.55 8.28 8.85 2kvaA1 THR 587 HA 0.01 0.14 0.89 -0.75 4.39 4.67 2kvaA1 THR 587 HB 0.07 -0.02 0.12 -0.04 4.32 4.44 2kvaA1 THR 587 HG23 -0.13 -0.01 0.05 -0.04 1.22 1.08 2kvaA1 GLU 588 H -0.07 0.16 0.27 -0.55 8.60 8.42 2kvaA1 GLU 588 HA -0.04 0.25 1.29 -0.75 4.29 5.04 2kvaA1 GLU 588 HB2 -0.05 -0.06 0.15 -0.04 2.09 2.09 2kvaA1 GLU 588 HB3 -0.04 0.15 0.13 -0.04 1.99 2.19 2kvaA1 GLU 588 HG2 -0.02 0.03 -0.12 -0.04 2.34 2.19 2kvaA1 GLU 588 HG3 -0.01 -0.03 -0.25 -0.04 2.34 2.00 2kvaA1 GLY 589 H -0.06 0.88 0.44 -0.55 8.43 9.14 2kvaA1 GLY 589 HA2 -0.24 0.14 0.97 -0.51 4.01 4.37 2kvaA1 GLY 589 HA3 -0.06 0.16 0.52 -0.51 4.01 4.12 2kvaA1 ASP 590 H 0.09 0.25 0.16 -0.55 8.40 8.35 2kvaA1 ASP 590 HA 0.01 0.06 0.87 -0.75 4.63 4.81 2kvaA1 ASP 590 HB2 0.03 0.08 -0.20 -0.04 2.71 2.57 2kvaA1 ASP 590 HB3 0.07 0.01 0.03 -0.04 2.70 2.77 2kvaA1 ASN 591 H 0.01 0.07 -0.01 -0.55 8.53 8.05 2kvaA1 ASN 591 HA 0.01 -0.04 0.44 -0.75 4.76 4.42 2kvaA1 ASN 591 HB2 0.02 -0.02 -0.03 -0.04 2.88 2.81 2kvaA1 ASN 591 HB3 0.03 0.16 0.08 -0.04 2.79 3.02 2kvaA1 ASN 591 HD21 0.01 0.01 -0.00 -0.04 7.03 7.01 2kvaA1 ASN 591 HD22 0.02 0.01 0.03 -0.04 7.74 7.75 2kvaA1 CYS 592 H -0.00 0.47 0.24 -0.55 8.50 8.66 2kvaA1 CYS 592 HA -0.02 0.07 0.24 -0.75 4.58 4.11 2kvaA1 CYS 592 HB2 0.01 0.21 -0.21 -0.04 2.97 2.94 2kvaA1 CYS 592 HB3 -0.01 -0.13 0.06 -0.04 2.97 2.86 2kvaA1 THR 593 H 0.03 0.13 -0.63 -0.55 8.28 7.25 2kvaA1 THR 593 HA 0.04 0.17 1.20 -0.75 4.39 5.04 2kvaA1 THR 593 HB 0.12 -0.01 0.05 -0.04 4.32 4.44 2kvaA1 THR 593 HG23 0.02 0.05 -0.06 -0.04 1.22 1.19 2kvaA1 VAL 594 H 0.12 0.90 0.32 -0.55 8.24 9.03 2kvaA1 VAL 594 HA 0.01 0.02 0.61 -0.75 4.13 4.02 2kvaA1 VAL 594 HB 0.05 0.01 -0.26 -0.04 2.12 1.87 2kvaA1 VAL 594 HG13 0.14 0.00 -0.18 -0.04 0.97 0.89 2kvaA1 VAL 594 HG23 0.09 0.01 -0.34 -0.04 0.95 0.67 2kvaA1 PHE 595 H -0.27 0.27 0.07 -0.55 8.34 7.85 2kvaA1 PHE 595 HA 0.06 0.29 0.92 -0.75 4.62 5.14 2kvaA1 PHE 595 HB2 0.00 0.07 0.05 -0.04 3.15 3.23 2kvaA1 PHE 595 HB3 -0.01 -0.00 -0.05 -0.04 3.06 2.96 2kvaA1 PHE 595 HD2 0.01 -0.04 -0.18 -0.04 7.28 7.02 2kvaA1 PHE 595 HE2 0.01 -0.01 0.00 -0.04 7.38 7.34 2kvaA1 PHE 595 HZ 0.01 0.01 0.02 -0.04 7.32 7.32 2kvaA1 ASP 596 H 0.20 0.93 0.28 -0.55 8.40 9.27 2kvaA1 ASP 596 HA 0.02 0.14 0.89 -0.75 4.63 4.93 2kvaA1 ASP 596 HB2 -0.06 0.12 -0.10 -0.04 2.71 2.63 2kvaA1 ASP 596 HB3 0.08 -0.12 0.21 -0.04 2.70 2.84 2kvaA1 SER 597 H 0.09 0.26 0.14 -0.55 8.46 8.40 2kvaA1 SER 597 HA 0.12 0.16 0.51 -0.75 4.49 4.53 2kvaA1 SER 597 HB2 0.08 0.00 0.08 -0.04 3.95 4.07 2kvaA1 SER 597 HB3 0.08 0.07 0.09 -0.04 3.93 4.13 2kvaA1 GLN 598 H 0.08 -0.04 -0.24 -0.55 8.47 7.72 2kvaA1 GLN 598 HA 0.05 0.17 0.39 -0.75 4.36 4.22 2kvaA1 GLN 598 HB2 0.07 -0.08 0.07 -0.04 2.15 2.17 2kvaA1 GLN 598 HB3 0.06 0.06 0.02 -0.04 2.02 2.11 2kvaA1 GLN 598 HG2 0.05 0.07 0.01 -0.04 2.40 2.49 2kvaA1 GLN 598 HG3 0.06 -0.11 0.02 -0.04 2.39 2.32 2kvaA1 GLN 598 HE21 0.06 0.04 -0.00 -0.04 6.97 7.03 2kvaA1 GLN 598 HE22 0.06 -0.16 0.09 -0.04 7.69 7.63 2kvaA1 ALA 599 H 0.09 -0.08 -0.10 -0.55 8.40 7.76 2kvaA1 ALA 599 HA 0.07 0.22 0.71 -0.75 4.34 4.60 2kvaA1 ALA 599 HB3 0.11 -0.00 -0.01 -0.04 1.41 1.47 2kvaA1 GLY 600 H 0.10 0.04 -0.21 -0.55 8.43 7.82 2kvaA1 GLY 600 HA2 0.08 0.04 0.30 -0.51 4.01 3.92 2kvaA1 GLY 600 HA3 0.07 0.13 0.53 -0.51 4.01 4.22 2kvaA1 PHE 601 H 0.18 0.24 0.20 -0.55 8.34 8.40 2kvaA1 PHE 601 HA -0.00 0.25 0.79 -0.75 4.62 4.90 2kvaA1 PHE 601 HB2 -0.08 0.05 -0.14 -0.04 3.15 2.94 2kvaA1 PHE 601 HB3 -0.24 -0.17 0.05 -0.04 3.06 2.66 2kvaA1 PHE 601 HD2 -0.17 -0.05 -0.24 -0.04 7.28 6.78 2kvaA1 PHE 601 HE2 -0.04 0.02 -0.19 -0.04 7.38 7.12 2kvaA1 PHE 601 HZ -0.27 0.10 -0.17 -0.04 7.32 6.94 2kvaA1 SER 602 H -0.51 0.30 0.13 -0.55 8.46 7.83 2kvaA1 SER 602 HA -0.01 0.16 0.89 -0.75 4.49 4.77 2kvaA1 SER 602 HB2 -0.12 0.01 -0.02 -0.04 3.95 3.78 2kvaA1 SER 602 HB3 -0.04 0.01 -0.12 -0.04 3.93 3.74 2kvaA1 PHE 603 H 0.04 0.84 0.34 -0.55 8.34 9.01 2kvaA1 PHE 603 HA -0.16 0.16 0.81 -0.75 4.62 4.67 2kvaA1 PHE 603 HB2 -0.10 -0.04 -0.07 -0.04 3.15 2.89 2kvaA1 PHE 603 HB3 -0.05 -0.02 -0.13 -0.04 3.06 2.81 2kvaA1 PHE 603 HD2 -0.74 -0.13 -0.13 -0.04 7.28 6.23 2kvaA1 PHE 603 HE2 -0.11 -0.12 -0.01 -0.04 7.38 7.10 2kvaA1 PHE 603 HZ -0.06 0.15 0.08 -0.04 7.32 7.45 2kvaA1 ASP 604 H 0.04 0.31 0.19 -0.55 8.40 8.40 2kvaA1 ASP 604 HA 0.03 0.22 1.08 -0.75 4.63 5.20 2kvaA1 ASP 604 HB2 -0.00 -0.01 0.12 -0.04 2.71 2.77 2kvaA1 ASP 604 HB3 -0.01 0.03 -0.00 -0.04 2.70 2.68 2kvaA1 LEU 605 H -0.04 0.74 0.26 -0.55 8.37 8.79 2kvaA1 LEU 605 HA -0.17 0.24 0.97 -0.75 4.35 4.64 2kvaA1 LEU 605 HB2 -0.22 0.05 -0.03 -0.04 1.64 1.40 2kvaA1 LEU 605 HB3 -0.36 -0.02 0.09 -0.04 1.64 1.30 2kvaA1 LEU 605 HG -0.17 -0.02 -0.28 -0.04 1.64 1.13 2kvaA1 LEU 605 HD13 -1.17 -0.00 -0.14 -0.04 0.93 -0.43 2kvaA1 LEU 605 HD23 -0.35 0.00 -0.23 -0.04 0.89 0.26 2kvaA1 THR 606 H -0.03 0.11 -0.17 -0.55 8.28 7.65 2kvaA1 THR 606 HA -0.00 0.05 0.41 -0.75 4.39 4.09 2kvaA1 THR 606 HB 0.00 0.05 0.05 -0.04 4.32 4.38 2kvaA1 THR 606 HG23 0.01 -0.01 -0.06 -0.04 1.22 1.13 2kvaA1 PRO 607 HA 0.03 0.11 0.45 -0.51 4.44 4.52 2kvaA1 PRO 607 HB2 0.09 0.04 -0.02 -0.04 2.28 2.34 2kvaA1 PRO 607 HB3 0.06 0.01 0.08 -0.04 2.02 2.13 2kvaA1 PRO 607 HG2 -0.02 0.06 -0.02 -0.04 2.03 2.00 2kvaA1 PRO 607 HG3 0.10 0.05 0.03 -0.04 2.03 2.17 2kvaA1 PRO 607 HD2 -0.02 0.02 -0.19 -0.04 3.68 3.45 2kvaA1 PRO 607 HD3 0.01 0.10 0.04 -0.04 3.65 3.76 2kvaA1 LEU 608 H -0.14 0.13 -0.69 -0.55 8.37 7.12 2kvaA1 LEU 608 HA -0.04 0.05 0.54 -0.75 4.35 4.15 2kvaA1 LEU 608 HB2 -0.64 -0.08 0.08 -0.04 1.64 0.96 2kvaA1 LEU 608 HB3 -0.23 0.10 0.03 -0.04 1.64 1.50 2kvaA1 LEU 608 HG -0.27 -0.11 0.14 -0.04 1.64 1.35 2kvaA1 LEU 608 HD13 -0.70 0.00 0.01 -0.04 0.93 0.20 2kvaA1 LEU 608 HD23 -0.08 0.02 -0.00 -0.04 0.89 0.78 2kvaA1 THR 609 H 0.01 0.19 -0.28 -0.55 8.28 7.65 2kvaA1 THR 609 HA 0.24 -0.13 0.56 -0.75 4.39 4.31 2kvaA1 THR 609 HB 0.05 0.27 0.23 -0.04 4.32 4.84 2kvaA1 THR 609 HG23 0.11 -0.07 -0.11 -0.04 1.22 1.11 2kvaA1 LYS 610 H 0.28 0.11 0.25 -0.55 8.42 8.51 2kvaA1 LYS 610 HA 0.06 0.23 0.98 -0.75 4.32 4.84 2kvaA1 LYS 610 HB2 -0.05 -0.07 0.12 -0.04 1.87 1.82 2kvaA1 LYS 610 HB3 -0.05 -0.10 0.07 -0.04 1.79 1.66 2kvaA1 LYS 610 HG2 0.02 0.11 -0.14 -0.04 1.46 1.41 2kvaA1 LYS 610 HG3 0.05 0.10 -0.13 -0.04 1.46 1.43 2kvaA1 LYS 610 HD2 -0.77 0.06 -0.10 -0.04 1.69 0.84 2kvaA1 LYS 610 HD3 -0.18 -0.04 -0.02 -0.04 1.68 1.40 2kvaA1 LYS 610 HE2 -0.16 0.05 -0.02 -0.04 2.99 2.83 2kvaA1 LYS 610 HE3 -0.18 -0.03 -0.00 -0.04 2.99 2.73 2kvaA1 LYS 611 H 0.03 0.22 0.15 -0.55 8.42 8.27 2kvaA1 LYS 611 HA 0.05 0.22 0.49 -0.75 4.32 4.33 2kvaA1 LYS 611 HB2 0.02 0.04 0.08 -0.04 1.87 1.97 2kvaA1 LYS 611 HB3 0.03 0.03 0.09 -0.04 1.79 1.90 2kvaA1 LYS 611 HG2 0.02 -0.04 0.12 -0.04 1.46 1.52 2kvaA1 LYS 611 HG3 0.01 0.04 -0.11 -0.04 1.46 1.35 2kvaA1 LYS 611 HD2 0.01 0.01 -0.02 -0.04 1.69 1.66 2kvaA1 LYS 611 HD3 0.02 0.01 0.02 -0.04 1.68 1.69 2kvaA1 LYS 611 HE2 0.01 -0.00 0.01 -0.04 2.99 2.98 2kvaA1 LYS 611 HE3 0.01 0.00 -0.02 -0.04 2.99 2.94 2kvaA1 ASP 612 H 0.00 -0.00 -0.19 -0.55 8.40 7.66 2kvaA1 ASP 612 HA 0.00 0.10 0.52 -0.75 4.63 4.50 2kvaA1 ASP 612 HB2 -0.01 -0.06 0.07 -0.04 2.71 2.67 2kvaA1 ASP 612 HB3 -0.04 0.01 0.05 -0.04 2.70 2.69 2kvaA1 ALA 613 H 0.01 -0.07 -0.54 -0.55 8.40 7.26 2kvaA1 ALA 613 HA 0.14 0.02 0.40 -0.75 4.34 4.14 2kvaA1 ALA 613 HB3 0.10 0.08 -0.00 -0.04 1.41 1.54 2kvaA1 TYR 614 H 0.30 0.70 0.40 -0.55 8.29 9.15 2kvaA1 TYR 614 HA -0.00 0.10 0.84 -0.75 4.56 4.75 2kvaA1 TYR 614 HB2 -0.08 0.08 0.08 -0.04 3.06 3.10 2kvaA1 TYR 614 HB3 -0.35 0.02 0.04 -0.04 2.98 2.65 2kvaA1 TYR 614 HD2 -0.03 -0.01 0.12 -0.04 7.15 7.18 2kvaA1 TYR 614 HE2 0.15 -0.02 0.09 -0.04 6.85 7.02 2kvaA1 LYS 615 H 0.03 0.17 0.24 -0.55 8.42 8.31 2kvaA1 LYS 615 HA -0.23 0.36 1.22 -0.75 4.32 4.91 2kvaA1 LYS 615 HB2 -0.21 0.01 0.03 -0.04 1.87 1.66 2kvaA1 LYS 615 HB3 -0.04 0.05 -0.07 -0.04 1.79 1.70 2kvaA1 LYS 615 HG2 0.08 0.01 -0.01 -0.04 1.46 1.50 2kvaA1 LYS 615 HG3 0.09 -0.04 0.13 -0.04 1.46 1.60 2kvaA1 LYS 615 HD2 0.16 -0.02 0.00 -0.04 1.69 1.78 2kvaA1 LYS 615 HD3 0.24 0.00 -0.10 -0.04 1.68 1.78 2kvaA1 LYS 615 HE2 0.03 0.05 -0.24 -0.04 2.99 2.78 2kvaA1 LYS 615 HE3 0.07 0.00 -0.08 -0.04 2.99 2.94 2kvaA1 VAL 616 H -0.13 0.85 0.41 -0.55 8.24 8.82 2kvaA1 VAL 616 HA 0.09 0.18 0.86 -0.75 4.13 4.51 2kvaA1 VAL 616 HB 0.28 -0.15 -0.01 -0.04 2.12 2.21 2kvaA1 VAL 616 HG13 0.14 0.16 0.15 -0.04 0.97 1.39 2kvaA1 VAL 616 HG23 -0.08 -0.03 -0.25 -0.04 0.95 0.54 2kvaA1 GLU 617 H 0.21 0.24 0.21 -0.55 8.60 8.71 2kvaA1 GLU 617 HA 0.13 0.18 1.21 -0.75 4.29 5.05 2kvaA1 GLU 617 HB2 0.06 0.12 0.08 -0.04 2.09 2.31 2kvaA1 GLU 617 HB3 0.06 0.02 -0.07 -0.04 1.99 1.96 2kvaA1 GLU 617 HG2 0.12 -0.04 0.02 -0.04 2.34 2.40 2kvaA1 GLU 617 HG3 0.10 -0.01 -0.03 -0.04 2.34 2.36 2kvaA1 THR 618 H 0.09 0.73 0.37 -0.55 8.28 8.93 2kvaA1 THR 618 HA 0.12 0.22 0.78 -0.75 4.39 4.75 2kvaA1 THR 618 HB 0.13 -0.13 0.21 -0.04 4.32 4.49 2kvaA1 THR 618 HG23 0.30 0.04 -0.25 -0.04 1.22 1.27 2kvaA1 ASP 619 H 0.04 0.15 0.16 -0.55 8.40 8.21 2kvaA1 ASP 619 HA -0.01 0.19 0.52 -0.75 4.63 4.58 2kvaA1 ASP 619 HB2 -0.01 -0.04 0.11 -0.04 2.71 2.74 2kvaA1 ASP 619 HB3 -0.02 0.05 0.06 -0.04 2.70 2.75 2kvaA1 LYS 620 H -0.08 -0.01 -0.09 -0.55 8.42 7.69 2kvaA1 LYS 620 HA -0.26 0.14 0.73 -0.75 4.32 4.17 2kvaA1 LYS 620 HB2 -0.49 -0.01 0.09 -0.04 1.87 1.41 2kvaA1 LYS 620 HB3 -1.05 0.01 0.01 -0.04 1.79 0.72 2kvaA1 LYS 620 HG2 -0.19 0.04 -0.02 -0.04 1.46 1.26 2kvaA1 LYS 620 HG3 -0.11 -0.05 0.01 -0.04 1.46 1.27 2kvaA1 LYS 620 HD2 -0.18 0.01 -0.01 -0.04 1.69 1.47 2kvaA1 LYS 620 HD3 -0.06 0.03 -0.01 -0.04 1.68 1.61 2kvaA1 LYS 620 HE2 0.05 -0.01 0.00 -0.04 2.99 3.00 2kvaA1 LYS 620 HE3 0.03 -0.01 -0.03 -0.04 2.99 2.94 2kvaA1 TYR 621 H -0.13 0.06 -0.02 -0.55 8.29 7.64 2kvaA1 TYR 621 HA -0.12 0.15 0.99 -0.75 4.56 4.84 2kvaA1 TYR 621 HB2 -0.93 -0.03 -0.20 -0.04 3.06 1.86 2kvaA1 TYR 621 HB3 -0.53 0.09 -0.20 -0.04 2.98 2.30 2kvaA1 TYR 621 HD2 0.06 0.00 -0.16 -0.04 7.15 7.01 2kvaA1 TYR 621 HE2 0.01 0.02 -0.09 -0.04 6.85 6.74 2kvaA1 GLU 622 H -0.08 0.89 0.34 -0.55 8.60 9.20 2kvaA1 GLU 622 HA -0.05 0.16 1.10 -0.75 4.29 4.74 2kvaA1 GLU 622 HB2 -0.06 0.09 0.10 -0.04 2.09 2.17 2kvaA1 GLU 622 HB3 0.00 -0.02 0.07 -0.04 1.99 2.00 2kvaA1 GLU 622 HG2 0.03 0.18 0.10 -0.04 2.34 2.61 2kvaA1 GLU 622 HG3 0.10 -0.11 0.04 -0.04 2.34 2.34 2kvaA1 PHE 623 H 0.10 0.82 0.34 -0.55 8.34 9.06 2kvaA1 PHE 623 HA 0.01 0.20 0.97 -0.75 4.62 5.04 2kvaA1 PHE 623 HB2 -0.07 -0.04 -0.04 -0.04 3.15 2.96 2kvaA1 PHE 623 HB3 -0.13 0.04 -0.15 -0.04 3.06 2.77 2kvaA1 PHE 623 HD2 0.07 0.04 -0.26 -0.04 7.28 7.10 2kvaA1 PHE 623 HE2 -0.17 0.00 -0.20 -0.04 7.38 6.97 2kvaA1 PHE 623 HZ -0.46 -0.02 -0.19 -0.04 7.32 6.61 2kvaA1 HIS 624 H 0.15 0.79 0.35 -0.55 8.41 9.16 2kvaA1 HIS 624 HA 0.02 0.37 1.15 -0.75 4.63 5.41 2kvaA1 HIS 624 HB2 -0.01 -0.06 0.09 -0.04 3.26 3.25 2kvaA1 HIS 624 HB3 0.01 0.08 -0.03 -0.04 3.20 3.21 2kvaA1 HIS 624 HD2 -0.01 0.02 -0.26 -0.04 6.97 6.69 2kvaA1 HIS 624 HE1 0.02 -0.02 -0.08 -0.04 7.75 7.62 2kvaA1 ILE 625 H 0.05 0.74 0.23 -0.55 8.25 8.72 2kvaA1 ILE 625 HA -0.07 0.26 0.86 -0.75 4.18 4.47 2kvaA1 ILE 625 HB -0.05 -0.03 -0.18 -0.04 1.89 1.59 2kvaA1 ILE 625 HG12 -0.32 0.03 -0.36 -0.04 1.49 0.80 2kvaA1 ILE 625 HG23 -0.03 0.00 -0.21 -0.04 0.93 0.65 2kvaA1 ILE 625 HG13 -0.49 -0.04 -0.43 -0.04 1.21 0.22 2kvaA1 ILE 625 HD13 -0.39 0.03 -0.23 -0.04 0.88 0.25 2kvaA1 ASN 626 H 0.06 0.53 0.17 -0.55 8.53 8.74 2kvaA1 ASN 626 HA 0.41 0.04 0.65 -0.75 4.76 5.11 2kvaA1 ASN 626 HB2 0.16 -0.03 -0.20 -0.04 2.88 2.77 2kvaA1 ASN 626 HB3 0.14 0.11 -0.30 -0.04 2.79 2.70 2kvaA1 ASN 626 HD21 0.12 -0.15 -0.03 -0.04 7.03 6.93 2kvaA1 ASN 626 HD22 0.11 0.60 0.04 -0.04 7.74 8.45 2kvaA1 VAL 627 H 0.26 0.11 0.11 -0.55 8.24 8.17 2kvaA1 VAL 627 HA 0.01 0.05 0.29 -0.75 4.13 3.73 2kvaA1 VAL 627 HB 0.02 -0.01 0.02 -0.04 2.12 2.11 2kvaA1 VAL 627 HG13 -0.27 -0.02 -0.09 -0.04 0.97 0.56 2kvaA1 VAL 627 HG23 -0.14 -0.00 -0.18 -0.04 0.95 0.59 2kvaA1 CYS 628 H 0.13 0.14 -0.07 -0.55 8.50 8.16 2kvaA1 CYS 628 HA 0.09 0.31 0.70 -0.75 4.58 4.93 2kvaA1 CYS 628 HB2 0.02 -0.13 0.16 -0.04 2.97 2.98 2kvaA1 CYS 628 HB3 -0.01 0.06 -0.10 -0.04 2.97 2.89 2kvaA1 GLY 629 H 0.16 0.66 0.12 -0.55 8.43 8.83 2kvaA1 GLY 629 HA2 0.10 -0.09 0.15 -0.51 4.01 3.66 2kvaA1 GLY 629 HA3 0.09 0.21 0.55 -0.51 4.01 4.35 2kvaA1 PRO 630 HA 0.02 0.10 0.26 -0.51 4.44 4.31 2kvaA1 PRO 630 HB2 0.01 0.11 -0.15 -0.04 2.28 2.21 2kvaA1 PRO 630 HB3 0.03 -0.10 -0.30 -0.04 2.02 1.61 2kvaA1 PRO 630 HG2 0.03 0.04 -0.06 -0.04 2.03 2.00 2kvaA1 PRO 630 HG3 0.03 0.04 0.03 -0.04 2.03 2.09 2kvaA1 PRO 630 HD2 0.06 0.15 0.19 -0.04 3.68 4.03 2kvaA1 PRO 630 HD3 0.06 0.00 0.15 -0.04 3.65 3.82 2kvaA1 VAL 631 H -0.02 0.72 0.27 -0.55 8.24 8.67 2kvaA1 VAL 631 HA 0.04 0.17 0.77 -0.75 4.13 4.36 2kvaA1 VAL 631 HB 0.04 0.05 -0.28 -0.04 2.12 1.90 2kvaA1 VAL 631 HG13 -0.01 0.00 -0.65 -0.04 0.97 0.26 2kvaA1 VAL 631 HG23 -0.01 0.03 -0.42 -0.04 0.95 0.51 2kvaA1 SER 632 H 0.02 0.22 -0.13 -0.55 8.46 8.02 2kvaA1 SER 632 HA -0.02 0.13 0.99 -0.75 4.49 4.84 2kvaA1 SER 632 HB2 0.00 0.15 0.10 -0.04 3.95 4.16 2kvaA1 SER 632 HB3 -0.00 0.01 0.20 -0.04 3.93 4.10 2kvaA1 VAL 633 H -0.05 0.33 0.08 -0.55 8.24 8.04 2kvaA1 VAL 633 HA -0.15 0.13 0.58 -0.75 4.13 3.94 2kvaA1 VAL 633 HB -0.13 -0.10 -0.02 -0.04 2.12 1.83 2kvaA1 VAL 633 HG13 -0.42 0.07 -0.07 -0.04 0.97 0.51 2kvaA1 VAL 633 HG23 -0.28 -0.03 -0.35 -0.04 0.95 0.26 2kvaA1 GLY 634 H -0.09 0.21 0.03 -0.55 8.43 8.04 2kvaA1 GLY 634 HA2 -0.05 0.16 0.56 -0.51 4.01 4.17 2kvaA1 GLY 634 HA3 -0.05 0.04 0.39 -0.51 4.01 3.88 2kvaA1 ALA 635 H -0.08 0.34 -0.64 -0.55 8.40 7.47 2kvaA1 ALA 635 HA -0.06 0.09 0.42 -0.75 4.34 4.03 2kvaA1 ALA 635 HB3 -0.08 0.02 -0.15 -0.04 1.41 1.16 2kvaA1 CYS 636 H -0.08 0.14 0.06 -0.55 8.50 8.08 2kvaA1 CYS 636 HA -0.05 0.21 0.86 -0.75 4.58 4.84 2kvaA1 CYS 636 HB2 -0.07 0.02 -0.08 -0.04 2.97 2.80 2kvaA1 CYS 636 HB3 -0.04 0.03 -0.01 -0.04 2.97 2.90 2kvaA1 PRO 637 HA -0.02 0.15 0.47 -0.51 4.44 4.53 2kvaA1 PRO 637 HB2 -0.01 -0.08 0.00 -0.04 2.28 2.15 2kvaA1 PRO 637 HB3 -0.02 0.08 0.10 -0.04 2.02 2.14 2kvaA1 PRO 637 HG2 -0.01 -0.04 0.10 -0.04 2.03 2.03 2kvaA1 PRO 637 HG3 -0.01 0.07 0.07 -0.04 2.03 2.12 2kvaA1 PRO 637 HD2 -0.03 0.07 0.19 -0.04 3.68 3.87 2kvaA1 PRO 637 HD3 -0.03 0.19 0.15 -0.04 3.65 3.91 2kvaA1 PRO 638 HA -0.01 0.32 0.48 -0.51 4.44 4.71 2kvaA1 PRO 638 HB2 -0.00 -0.01 0.14 -0.04 2.28 2.37 2kvaA1 PRO 638 HB3 -0.00 0.05 0.16 -0.04 2.02 2.19 2kvaA1 PRO 638 HG2 -0.01 0.00 0.09 -0.04 2.03 2.08 2kvaA1 PRO 638 HG3 -0.02 0.09 0.14 -0.04 2.03 2.20 2kvaA1 PRO 638 HD2 -0.01 0.07 0.15 -0.04 3.68 3.85 2kvaA1 PRO 638 HD3 -0.02 0.17 0.30 -0.04 3.65 4.06 2kvaA1 ASP 639 H -0.01 0.20 -1.21 -0.55 8.40 6.83 2kvaA1 ASP 639 HA 0.02 0.20 0.80 -0.75 4.63 4.89 2kvaA1 ASP 639 HB2 0.01 0.02 -0.12 -0.04 2.71 2.58 2kvaA1 ASP 639 HB3 0.00 -0.00 -0.02 -0.04 2.70 2.64 2kvaA1 SER 640 H -0.01 0.45 0.19 -0.55 8.46 8.54 2kvaA1 SER 640 HA -0.01 0.03 1.22 -0.75 4.49 4.98 2kvaA1 SER 640 HB2 -0.04 0.08 0.09 -0.04 3.95 4.03 2kvaA1 SER 640 HB3 -0.01 -0.04 0.06 -0.04 3.93 3.89 2kvaA1 GLY 641 H -0.13 0.47 -0.02 -0.55 8.43 8.20 2kvaA1 GLY 641 HA2 -0.15 0.02 0.78 -0.51 4.01 4.16 2kvaA1 GLY 641 HA3 -0.45 0.16 0.28 -0.51 4.01 3.49 2kvaA1 ALA 642 H -0.25 0.27 -0.08 -0.55 8.40 7.79 2kvaA1 ALA 642 HA -0.19 0.33 0.61 -0.75 4.34 4.34 2kvaA1 ALA 642 HB3 -0.26 0.00 -0.20 -0.04 1.41 0.91 2kvaA1 CYS 643 H 0.00 0.76 0.24 -0.55 8.50 8.96 2kvaA1 CYS 643 HA 0.03 0.10 0.98 -0.75 4.58 4.93 2kvaA1 CYS 643 HB2 -0.01 -0.01 -0.19 -0.04 2.97 2.72 2kvaA1 CYS 643 HB3 0.01 0.02 -0.04 -0.04 2.97 2.93 2kvaA1 GLN 644 H 0.09 0.69 0.33 -0.55 8.47 9.04 2kvaA1 GLN 644 HA -0.03 0.35 1.21 -0.75 4.36 5.13 2kvaA1 GLN 644 HB2 -0.47 -0.03 -0.14 -0.04 2.15 1.47 2kvaA1 GLN 644 HB3 -0.07 -0.04 -0.14 -0.04 2.02 1.72 2kvaA1 GLN 644 HG2 0.08 0.07 -0.01 -0.04 2.40 2.51 2kvaA1 GLN 644 HG3 0.34 -0.05 -0.09 -0.04 2.39 2.54 2kvaA1 GLN 644 HE21 -0.40 0.03 -0.11 -0.04 6.97 6.44 2kvaA1 GLN 644 HE22 -0.27 0.02 -0.15 -0.04 7.69 7.25 2kvaA1 VAL 645 H -0.01 0.86 0.36 -0.55 8.24 8.90 2kvaA1 VAL 645 HA 0.02 0.25 1.06 -0.75 4.13 4.70 2kvaA1 VAL 645 HB 0.07 -0.04 0.08 -0.04 2.12 2.19 2kvaA1 VAL 645 HG13 0.01 0.00 -0.28 -0.04 0.97 0.66 2kvaA1 VAL 645 HG23 0.01 -0.01 -0.23 -0.04 0.95 0.67 2kvaA1 SER 646 H 0.11 0.98 0.26 -0.55 8.46 9.25 2kvaA1 SER 646 HA 0.29 0.07 0.74 -0.75 4.49 4.83 2kvaA1 SER 646 HB2 0.75 0.10 0.09 -0.04 3.95 4.86 2kvaA1 SER 646 HB3 0.15 -0.20 0.15 -0.04 3.93 3.99 2kvaA1 ARG 647 H -0.03 0.78 0.45 -0.55 8.46 9.11 2kvaA1 ARG 647 HA 0.00 0.21 0.83 -0.75 4.34 4.63 2kvaA1 ARG 647 HB2 -0.04 0.17 -0.06 -0.04 1.90 1.93 2kvaA1 ARG 647 HB3 -0.01 -0.01 0.02 -0.04 1.80 1.76 2kvaA1 ARG 647 HG2 0.01 0.01 -0.13 -0.04 1.67 1.52 2kvaA1 ARG 647 HG3 -0.01 -0.10 -0.26 -0.04 1.67 1.25 2kvaA1 ARG 647 HD2 0.01 -0.08 -0.16 -0.04 3.22 2.95 2kvaA1 ARG 647 HD3 -0.01 0.22 -0.19 -0.04 3.22 3.20 2kvaA1 SER 648 H -0.06 0.18 0.27 -0.55 8.46 8.31 2kvaA1 SER 648 HA -0.02 0.19 0.62 -0.75 4.49 4.52 2kvaA1 SER 648 HB2 -0.06 -0.08 0.19 -0.04 3.95 3.96 2kvaA1 SER 648 HB3 -0.03 0.02 0.08 -0.04 3.93 3.96 2kvaA1 ASP 649 H 0.05 -0.02 0.00 -0.55 8.40 7.89 2kvaA1 ASP 649 HA 0.04 0.27 0.70 -0.75 4.63 4.88 2kvaA1 ASP 649 HB2 0.12 0.01 -0.01 -0.04 2.71 2.78 2kvaA1 ASP 649 HB3 0.24 -0.06 0.05 -0.04 2.70 2.88 2kvaA1 ARG 650 H 0.03 -0.09 -0.51 -0.55 8.46 7.33 2kvaA1 ARG 650 HA -0.01 0.54 0.25 -0.75 4.34 4.36 2kvaA1 ARG 650 HB2 -0.02 0.08 -0.21 -0.04 1.90 1.70 2kvaA1 ARG 650 HB3 -0.03 -0.03 0.14 -0.04 1.80 1.84 2kvaA1 ARG 650 HG2 -0.01 0.08 -0.03 -0.04 1.67 1.67 2kvaA1 ARG 650 HG3 -0.00 -0.02 -0.47 -0.04 1.67 1.14 2kvaA1 ARG 650 HD2 -0.01 -0.02 -0.12 -0.04 3.22 3.03 2kvaA1 ARG 650 HD3 -0.01 -0.04 -0.03 -0.04 3.22 3.09 2kvaA1 LYS 651 H -0.08 -0.12 -0.46 -0.55 8.42 7.21 2kvaA1 LYS 651 HA -0.30 0.25 0.91 -0.75 4.32 4.42 2kvaA1 LYS 651 HB2 -0.70 -0.10 -0.03 -0.04 1.87 1.00 2kvaA1 LYS 651 HB3 -0.91 0.04 0.08 -0.04 1.79 0.96 2kvaA1 LYS 651 HG2 -0.21 0.04 0.01 -0.04 1.46 1.26 2kvaA1 LYS 651 HG3 -0.11 0.17 -0.09 -0.04 1.46 1.38 2kvaA1 LYS 651 HD2 0.04 -0.06 -0.02 -0.04 1.69 1.61 2kvaA1 LYS 651 HD3 -0.16 0.01 0.01 -0.04 1.68 1.50 2kvaA1 LYS 651 HE2 -0.05 0.01 0.01 -0.04 2.99 2.92 2kvaA1 LYS 651 HE3 0.01 0.04 0.01 -0.04 2.99 3.00 2kvaA1 SER 652 H -0.59 0.21 0.22 -0.55 8.46 7.75 2kvaA1 SER 652 HA -0.24 0.33 1.23 -0.75 4.49 5.06 2kvaA1 SER 652 HB2 -0.11 0.01 -0.02 -0.04 3.95 3.79 2kvaA1 SER 652 HB3 -0.14 -0.01 -0.09 -0.04 3.93 3.65 2kvaA1 TRP 653 H 0.17 0.67 0.38 -0.55 7.97 8.64 2kvaA1 TRP 653 HA -0.02 0.15 0.89 -0.75 4.62 4.88 2kvaA1 TRP 653 HB2 -0.07 -0.06 -0.03 -0.04 3.23 3.03 2kvaA1 TRP 653 HB3 -0.01 0.09 0.05 -0.04 3.23 3.32 2kvaA1 TRP 653 HD1 0.04 0.03 0.01 -0.04 7.22 7.26 2kvaA1 TRP 653 HE1 0.05 0.00 -0.05 -0.04 10.20 10.16 2kvaA1 TRP 653 HE3 -0.10 0.04 -0.16 -0.04 7.59 7.33 2kvaA1 TRP 653 HZ2 0.06 0.01 -0.07 -0.04 7.44 7.40 2kvaA1 TRP 653 HZ3 0.16 -0.07 -0.14 -0.04 7.13 7.03 2kvaA1 TRP 653 HH2 0.15 -0.08 -0.08 -0.04 7.19 7.15 2kvaA1 ASN 654 H 0.15 0.16 0.24 -0.55 8.53 8.54 2kvaA1 ASN 654 HA 0.04 0.22 1.04 -0.75 4.76 5.30 2kvaA1 ASN 654 HB2 0.05 -0.06 0.18 -0.04 2.88 3.01 2kvaA1 ASN 654 HB3 0.01 0.02 0.08 -0.04 2.79 2.85 2kvaA1 ASN 654 HD21 0.00 0.01 0.03 -0.04 7.03 7.03 2kvaA1 ASN 654 HD22 0.02 0.04 0.02 -0.04 7.74 7.77 2kvaA1 LEU 655 H -0.02 0.85 0.20 -0.55 8.37 8.86 2kvaA1 LEU 655 HA -0.04 0.15 0.78 -0.75 4.35 4.49 2kvaA1 LEU 655 HB2 -0.06 -0.01 -0.23 -0.04 1.64 1.30 2kvaA1 LEU 655 HB3 -0.14 0.01 -0.17 -0.04 1.64 1.30 2kvaA1 LEU 655 HG -0.30 0.04 -0.28 -0.04 1.64 1.06 2kvaA1 LEU 655 HD13 0.05 -0.01 -0.45 -0.04 0.93 0.47 2kvaA1 LEU 655 HD23 -0.21 0.01 -0.20 -0.04 0.89 0.44 2kvaA1 GLY 656 H -0.01 0.07 -0.16 -0.55 8.43 7.78 2kvaA1 GLY 656 HA2 0.05 -0.03 -0.78 -0.51 4.01 2.74 2kvaA1 GLY 656 HA3 0.10 0.07 0.32 -0.51 4.01 4.00 2kvaA1 ARG 657 H 0.06 0.40 0.05 -0.55 8.46 8.42 2kvaA1 ARG 657 HA 0.02 -0.02 0.78 -0.75 4.34 4.37 2kvaA1 ARG 657 HB2 0.03 0.09 0.33 -0.04 1.90 2.32 2kvaA1 ARG 657 HB3 0.06 0.04 0.26 -0.04 1.80 2.11 2kvaA1 ARG 657 HG2 0.04 0.07 0.11 -0.04 1.67 1.86 2kvaA1 ARG 657 HG3 0.03 0.07 0.25 -0.04 1.67 1.98 2kvaA1 ARG 657 HD2 0.02 -0.03 0.11 -0.04 3.22 3.28 2kvaA1 ARG 657 HD3 0.03 -0.03 0.08 -0.04 3.22 3.26 2kvaA1 SER 658 H 0.05 0.76 0.25 -0.55 8.46 8.97 2kvaA1 SER 658 HA 0.19 0.14 0.22 -0.75 4.49 4.29 2kvaA1 SER 658 HB2 0.10 -0.12 -0.44 -0.04 3.95 3.45 2kvaA1 SER 658 HB3 0.05 -0.06 -0.60 -0.04 3.93 3.29 2kvaA1 ASN 659 H 0.39 0.44 0.29 -0.55 8.53 9.10 2kvaA1 ASN 659 HA 0.05 0.07 0.75 -0.75 4.76 4.87 2kvaA1 ASN 659 HB2 0.06 0.19 -0.01 -0.04 2.88 3.09 2kvaA1 ASN 659 HB3 0.02 0.05 0.09 -0.04 2.79 2.91 2kvaA1 ASN 659 HD21 -0.23 0.14 0.17 -0.04 7.03 7.07 2kvaA1 ASN 659 HD22 -0.62 0.02 -0.13 -0.04 7.74 6.97 2kvaA1 ALA 660 H -0.02 0.18 0.25 -0.55 8.40 8.25 2kvaA1 ALA 660 HA -0.05 0.32 1.06 -0.75 4.34 4.91 2kvaA1 ALA 660 HB3 0.01 -0.02 0.15 -0.04 1.41 1.51 2kvaA1 LYS 661 H -0.11 0.11 0.11 -0.55 8.42 7.98 2kvaA1 LYS 661 HA -0.04 0.05 0.61 -0.75 4.32 4.20 2kvaA1 LYS 661 HB2 -0.09 0.06 0.24 -0.04 1.87 2.05 2kvaA1 LYS 661 HB3 -0.05 0.13 0.09 -0.04 1.79 1.93 2kvaA1 LYS 661 HG2 -0.02 0.09 0.18 -0.04 1.46 1.67 2kvaA1 LYS 661 HG3 -0.03 -0.21 0.17 -0.04 1.46 1.35 2kvaA1 LYS 661 HD2 -0.01 -0.02 0.07 -0.04 1.69 1.69 2kvaA1 LYS 661 HD3 -0.03 0.02 0.09 -0.04 1.68 1.72 2kvaA1 LYS 661 HE2 -0.02 0.05 0.04 -0.04 2.99 3.03 2kvaA1 LYS 661 HE3 -0.02 -0.02 0.02 -0.04 2.99 2.94 2kvaA1 LEU 662 H -0.03 0.16 0.14 -0.55 8.37 8.09 2kvaA1 LEU 662 HA -0.02 0.22 0.95 -0.75 4.35 4.74 2kvaA1 LEU 662 HB2 0.00 0.12 -0.18 -0.04 1.64 1.54 2kvaA1 LEU 662 HB3 0.02 0.05 -0.06 -0.04 1.64 1.61 2kvaA1 LEU 662 HG -0.04 -0.05 -0.28 -0.04 1.64 1.24 2kvaA1 LEU 662 HD13 -0.10 0.00 -0.36 -0.04 0.93 0.43 2kvaA1 LEU 662 HD23 -0.05 -0.01 -0.31 -0.04 0.89 0.48 2kvaA1 SER 663 H 0.05 0.86 0.42 -0.55 8.46 9.25 2kvaA1 SER 663 HA 0.03 0.26 1.08 -0.75 4.49 5.10 2kvaA1 SER 663 HB2 0.01 -0.04 -0.09 -0.04 3.95 3.80 2kvaA1 SER 663 HB3 0.02 -0.03 -0.07 -0.04 3.93 3.81 2kvaA1 TYR 664 H 0.12 0.73 0.29 -0.55 8.29 8.87 2kvaA1 TYR 664 HA -0.03 0.24 0.85 -0.75 4.56 4.87 2kvaA1 TYR 664 HB2 -0.03 0.03 -0.24 -0.04 3.06 2.78 2kvaA1 TYR 664 HB3 -0.07 -0.12 0.09 -0.04 2.98 2.85 2kvaA1 TYR 664 HD2 -0.18 -0.02 -0.18 -0.04 7.15 6.73 2kvaA1 TYR 664 HE2 -0.48 0.09 -0.16 -0.04 6.85 6.25 2kvaA1 TYR 665 H -0.19 1.01 0.16 -0.55 8.29 8.72 2kvaA1 TYR 665 HA -0.16 0.42 1.27 -0.75 4.56 5.34 2kvaA1 TYR 665 HB2 -0.10 -0.04 -0.09 -0.04 3.06 2.79 2kvaA1 TYR 665 HB3 -0.15 0.06 0.13 -0.04 2.98 2.98 2kvaA1 TYR 665 HD2 -0.11 -0.02 -0.24 -0.04 7.15 6.73 2kvaA1 TYR 665 HE2 -0.11 0.03 -0.16 -0.04 6.85 6.56 2kvaA1 ASP 666 H -0.37 0.44 0.19 -0.55 8.40 8.10 2kvaA1 ASP 666 HA -0.33 0.02 0.30 -0.75 4.63 3.87 2kvaA1 ASP 666 HB2 -0.73 -0.07 -0.00 -0.04 2.71 1.87 2kvaA1 ASP 666 HB3 -0.61 0.12 -0.12 -0.04 2.70 2.04 2kvaA1 GLY 667 H -1.02 -0.01 -0.60 -0.55 8.43 6.26 2kvaA1 GLY 667 HA2 -0.70 -0.03 0.22 -0.51 4.01 2.98 2kvaA1 GLY 667 HA3 -0.31 0.24 0.85 -0.51 4.01 4.28 2kvaA1 MET 668 H -0.45 0.55 -0.22 -0.55 8.47 7.80 2kvaA1 MET 668 HA -0.12 0.25 0.94 -0.75 4.52 4.84 2kvaA1 MET 668 HB2 -0.05 0.02 0.14 -0.04 2.15 2.22 2kvaA1 MET 668 HB3 -0.04 0.04 -0.02 -0.04 2.03 1.97 2kvaA1 MET 668 HG2 -0.06 0.03 -0.06 -0.04 2.63 2.50 2kvaA1 MET 668 HG3 -0.12 0.02 -0.11 -0.04 2.56 2.30 2kvaA1 MET 668 HE3 0.08 -0.01 -0.04 -0.04 2.10 2.10 2kvaA1 ILE 669 H 0.05 0.32 0.24 -0.55 8.25 8.30 2kvaA1 ILE 669 HA 0.18 0.16 0.93 -0.75 4.18 4.69 2kvaA1 ILE 669 HB 0.17 -0.04 0.10 -0.04 1.89 2.07 2kvaA1 ILE 669 HG12 0.33 -0.02 -0.05 -0.04 1.49 1.70 2kvaA1 ILE 669 HG23 0.30 0.00 -0.22 -0.04 0.93 0.97 2kvaA1 ILE 669 HG13 0.23 0.04 -0.05 -0.04 1.21 1.39 2kvaA1 ILE 669 HD13 -0.01 -0.03 -0.16 -0.04 0.88 0.64 2kvaA1 GLN 670 H 0.13 0.88 0.40 -0.55 8.47 9.33 2kvaA1 GLN 670 HA -0.08 0.30 1.08 -0.75 4.36 4.91 2kvaA1 GLN 670 HB2 -0.02 -0.11 -0.08 -0.04 2.15 1.90 2kvaA1 GLN 670 HB3 -0.07 0.06 0.05 -0.04 2.02 2.02 2kvaA1 GLN 670 HG2 -0.06 0.04 -0.17 -0.04 2.40 2.17 2kvaA1 GLN 670 HG3 -0.00 0.06 -0.39 -0.04 2.39 2.02 2kvaA1 GLN 670 HE21 -0.32 -0.02 -0.11 -0.04 6.97 6.48 2kvaA1 GLN 670 HE22 -0.04 -0.05 -0.14 -0.04 7.69 7.41 2kvaA1 LEU 671 H -0.14 0.68 0.39 -0.55 8.37 8.75 2kvaA1 LEU 671 HA -0.03 0.19 0.97 -0.75 4.35 4.73 2kvaA1 LEU 671 HB2 -0.09 -0.04 -0.08 -0.04 1.64 1.39 2kvaA1 LEU 671 HB3 -0.10 -0.15 0.04 -0.04 1.64 1.38 2kvaA1 LEU 671 HG 0.03 -0.02 -0.01 -0.04 1.64 1.60 2kvaA1 LEU 671 HD13 0.02 0.00 -0.10 -0.04 0.93 0.81 2kvaA1 LEU 671 HD23 -0.20 0.03 -0.03 -0.04 0.89 0.66 2kvaA1 THR 672 H -0.18 0.41 0.16 -0.55 8.28 8.13 2kvaA1 THR 672 HA -0.02 0.35 1.21 -0.75 4.39 5.18 2kvaA1 THR 672 HB -0.07 -0.02 0.04 -0.04 4.32 4.24 2kvaA1 THR 672 HG23 -0.01 -0.00 -0.16 -0.04 1.22 1.01 2kvaA1 TYR 673 H 0.12 0.83 0.36 -0.55 8.29 9.05 2kvaA1 TYR 673 HA 0.01 0.14 0.98 -0.75 4.56 4.94 2kvaA1 TYR 673 HB2 0.02 -0.04 0.07 -0.04 3.06 3.06 2kvaA1 TYR 673 HB3 0.02 0.00 -0.10 -0.04 2.98 2.86 2kvaA1 TYR 673 HD2 0.01 0.08 -0.14 -0.04 7.15 7.06 2kvaA1 TYR 673 HE2 0.02 -0.08 0.06 -0.04 6.85 6.80 2kvaA1 ARG 674 H 0.16 0.34 0.22 -0.55 8.46 8.62 2kvaA1 ARG 674 HA 0.07 0.24 0.93 -0.75 4.34 4.82 2kvaA1 ARG 674 HB2 0.03 -0.03 0.06 -0.04 1.90 1.92 2kvaA1 ARG 674 HB3 0.03 0.04 -0.17 -0.04 1.80 1.65 2kvaA1 ARG 674 HG2 0.03 0.00 0.06 -0.04 1.67 1.72 2kvaA1 ARG 674 HG3 0.04 0.03 -0.15 -0.04 1.67 1.55 2kvaA1 ARG 674 HD2 0.00 0.01 -0.04 -0.04 3.22 3.15 2kvaA1 ARG 674 HD3 0.01 -0.02 -0.00 -0.04 3.22 3.17 2kvaA1 ASP 675 H 0.03 0.19 0.10 -0.55 8.40 8.17 2kvaA1 ASP 675 HA 0.01 0.09 0.41 -0.75 4.63 4.39 2kvaA1 ASP 675 HB2 0.03 -0.00 -0.01 -0.04 2.71 2.68 2kvaA1 ASP 675 HB3 0.04 0.03 0.49 -0.04 2.70 3.22 2kvaA1 GLY 676 H 0.02 0.28 -0.14 -0.55 8.43 8.05 2kvaA1 GLY 676 HA2 0.03 0.04 0.63 -0.51 4.01 4.19 2kvaA1 GLY 676 HA3 0.03 0.17 -0.05 -0.51 4.01 3.64 2kvaA1 THR 677 H 0.08 0.75 0.28 -0.55 8.28 8.85 2kvaA1 THR 677 HA 0.06 0.14 0.58 -0.75 4.39 4.41 2kvaA1 THR 677 HB 0.30 0.00 0.26 -0.04 4.32 4.84 2kvaA1 THR 677 HG23 0.21 -0.00 -0.02 -0.04 1.22 1.37 2kvaA1 PRO 678 HA -0.42 0.14 0.48 -0.51 4.44 4.14 2kvaA1 PRO 678 HB2 -0.06 -0.02 -0.10 -0.04 2.28 2.06 2kvaA1 PRO 678 HB3 -0.15 0.11 -0.20 -0.04 2.02 1.74 2kvaA1 PRO 678 HG2 -0.03 0.02 0.03 -0.04 2.03 2.02 2kvaA1 PRO 678 HG3 -0.06 0.03 0.05 -0.04 2.03 2.01 2kvaA1 PRO 678 HD2 0.02 0.07 0.22 -0.04 3.68 3.94 2kvaA1 PRO 678 HD3 -0.00 0.26 0.40 -0.04 3.65 4.26 2kvaA1 TYR 679 H -0.68 0.31 0.21 -0.55 8.29 7.57 2kvaA1 TYR 679 HA 0.02 0.19 0.78 -0.75 4.56 4.79 2kvaA1 TYR 679 HB2 -0.03 -0.01 0.02 -0.04 3.06 3.00 2kvaA1 TYR 679 HB3 -0.07 0.06 0.01 -0.04 2.98 2.94 2kvaA1 TYR 679 HD2 -0.05 0.03 -0.20 -0.04 7.15 6.88 2kvaA1 TYR 679 HE2 0.02 -0.05 -0.01 -0.04 6.85 6.77 2kvaA1 ASN 680 H 0.15 0.15 0.10 -0.55 8.53 8.39 2kvaA1 ASN 680 HA 0.06 0.07 0.45 -0.75 4.76 4.58 2kvaA1 ASN 680 HB2 0.06 -0.00 0.21 -0.04 2.88 3.11 2kvaA1 ASN 680 HB3 0.05 0.01 0.06 -0.04 2.79 2.87 2kvaA1 ASN 680 HD21 0.05 0.02 0.02 -0.04 7.03 7.08 2kvaA1 ASN 680 HD22 0.05 -0.01 0.05 -0.04 7.74 7.79 2kvaA1 ASN 681 H 0.04 0.36 0.43 -0.55 8.53 8.82 2kvaA1 ASN 681 HA 0.06 0.15 0.67 -0.75 4.76 4.89 2kvaA1 ASN 681 HB2 0.20 0.16 -0.14 -0.04 2.88 3.06 2kvaA1 ASN 681 HB3 0.05 -0.07 0.04 -0.04 2.79 2.78 2kvaA1 ASN 681 HD21 0.05 0.01 -0.00 -0.04 7.03 7.04 2kvaA1 ASN 681 HD22 0.07 0.04 -0.03 -0.04 7.74 7.78 2kvaA1 GLU 682 H 0.03 0.18 0.15 -0.55 8.60 8.41 2kvaA1 GLU 682 HA 0.01 0.11 0.28 -0.75 4.29 3.94 2kvaA1 GLU 682 HB2 0.01 -0.02 0.12 -0.04 2.09 2.15 2kvaA1 GLU 682 HB3 0.01 0.06 0.05 -0.04 1.99 2.07 2kvaA1 GLU 682 HG2 0.01 0.04 0.05 -0.04 2.34 2.39 2kvaA1 GLU 682 HG3 0.01 -0.03 0.12 -0.04 2.34 2.40 2kvaA1 LYS 683 H 0.01 0.03 -0.15 -0.55 8.42 7.75 2kvaA1 LYS 683 HA -0.00 0.17 0.52 -0.75 4.32 4.26 2kvaA1 LYS 683 HB2 -0.00 0.06 0.07 -0.04 1.87 1.95 2kvaA1 LYS 683 HB3 0.00 -0.04 0.02 -0.04 1.79 1.74 2kvaA1 LYS 683 HG2 0.01 -0.11 -0.06 -0.04 1.46 1.26 2kvaA1 LYS 683 HG3 -0.01 0.05 -0.42 -0.04 1.46 1.04 2kvaA1 LYS 683 HD2 0.01 0.01 -0.08 -0.04 1.69 1.58 2kvaA1 LYS 683 HD3 -0.00 0.04 -0.06 -0.04 1.68 1.61 2kvaA1 LYS 683 HE2 0.00 0.01 -0.02 -0.04 2.99 2.93 2kvaA1 LYS 683 HE3 0.01 -0.04 -0.03 -0.04 2.99 2.89 2kvaA1 ARG 684 H -0.00 0.31 -0.59 -0.55 8.46 7.63 2kvaA1 ARG 684 HA -0.04 0.01 0.38 -0.75 4.34 3.93 2kvaA1 ARG 684 HB2 -0.03 -0.03 0.07 -0.04 1.90 1.88 2kvaA1 ARG 684 HB3 -0.01 0.02 0.07 -0.04 1.80 1.84 2kvaA1 ARG 684 HG2 -0.02 0.17 0.21 -0.04 1.67 1.99 2kvaA1 ARG 684 HG3 -0.01 -0.06 0.03 -0.04 1.67 1.59 2kvaA1 ARG 684 HD2 -0.01 -0.11 -0.70 -0.04 3.22 2.36 2kvaA1 ARG 684 HD3 -0.00 -0.04 -0.09 -0.04 3.22 3.04 2kvaA1 THR 685 H -0.09 0.04 -0.04 -0.55 8.28 7.64 2kvaA1 THR 685 HA -0.06 0.28 0.87 -0.75 4.39 4.72 2kvaA1 THR 685 HB -0.03 -0.03 -0.12 -0.04 4.32 4.10 2kvaA1 THR 685 HG23 -0.07 0.02 -0.07 -0.04 1.22 1.06 2kvaA1 PRO 686 HA -0.16 0.07 0.47 -0.51 4.44 4.32 2kvaA1 PRO 686 HB2 -0.02 -0.20 0.04 -0.04 2.28 2.06 2kvaA1 PRO 686 HB3 -0.03 0.32 0.16 -0.04 2.02 2.42 2kvaA1 PRO 686 HG2 -0.02 -0.03 0.12 -0.04 2.03 2.06 2kvaA1 PRO 686 HG3 -0.03 0.09 0.09 -0.04 2.03 2.13 2kvaA1 PRO 686 HD2 -0.04 0.05 0.21 -0.04 3.68 3.86 2kvaA1 PRO 686 HD3 -0.05 0.27 0.25 -0.04 3.65 4.08 2kvaA1 ARG 687 H -0.10 0.14 -0.63 -0.55 8.46 7.31 2kvaA1 ARG 687 HA 0.13 0.08 0.30 -0.75 4.34 4.09 2kvaA1 ARG 687 HB2 0.13 0.41 0.05 -0.04 1.90 2.45 2kvaA1 ARG 687 HB3 0.04 -0.15 0.10 -0.04 1.80 1.75 2kvaA1 ARG 687 HG2 -0.12 -0.03 -0.09 -0.04 1.67 1.39 2kvaA1 ARG 687 HG3 0.37 0.05 0.03 -0.04 1.67 2.07 2kvaA1 ARG 687 HD2 -0.08 -0.02 -0.24 -0.04 3.22 2.84 2kvaA1 ARG 687 HD3 -0.40 -0.06 -0.11 -0.04 3.22 2.61 2kvaA1 ALA 688 H 0.21 0.24 0.23 -0.55 8.40 8.53 2kvaA1 ALA 688 HA 0.10 0.34 0.96 -0.75 4.34 4.98 2kvaA1 ALA 688 HB3 0.08 -0.01 -0.00 -0.04 1.41 1.44 2kvaA1 THR 689 H 0.16 0.46 0.29 -0.55 8.28 8.64 2kvaA1 THR 689 HA 0.26 0.20 1.00 -0.75 4.39 5.10 2kvaA1 THR 689 HB 0.25 -0.07 0.03 -0.04 4.32 4.49 2kvaA1 THR 689 HG23 0.21 -0.01 -0.20 -0.04 1.22 1.18 2kvaA1 LEU 690 H 0.19 0.80 0.27 -0.55 8.37 9.08 2kvaA1 LEU 690 HA 0.04 0.45 1.30 -0.75 4.35 5.39 2kvaA1 LEU 690 HB2 0.02 -0.02 -0.16 -0.04 1.64 1.44 2kvaA1 LEU 690 HB3 0.01 -0.09 0.03 -0.04 1.64 1.54 2kvaA1 LEU 690 HG -0.05 0.21 0.02 -0.04 1.64 1.78 2kvaA1 LEU 690 HD13 -0.05 0.00 -0.10 -0.04 0.93 0.74 2kvaA1 LEU 690 HD23 -0.08 -0.02 -0.28 -0.04 0.89 0.48 2kvaA1 ILE 691 H -0.06 0.53 0.25 -0.55 8.25 8.43 2kvaA1 ILE 691 HA -0.01 0.08 0.90 -0.75 4.18 4.40 2kvaA1 ILE 691 HB -0.51 -0.04 0.04 -0.04 1.89 1.34 2kvaA1 ILE 691 HG12 0.03 0.04 -0.19 -0.04 1.49 1.32 2kvaA1 ILE 691 HG23 -0.92 0.00 -0.25 -0.04 0.93 -0.28 2kvaA1 ILE 691 HG13 0.10 -0.01 -0.19 -0.04 1.21 1.06 2kvaA1 ILE 691 HD13 -0.52 -0.04 -0.34 -0.04 0.88 -0.06 2kvaA1 THR 692 H -0.17 0.75 0.36 -0.55 8.28 8.67 2kvaA1 THR 692 HA -0.23 0.25 1.10 -0.75 4.39 4.76 2kvaA1 THR 692 HB -0.12 -0.03 0.17 -0.04 4.32 4.29 2kvaA1 THR 692 HG23 -0.07 0.01 -0.14 -0.04 1.22 0.98 2kvaA1 PHE 693 H -0.09 0.90 0.24 -0.55 8.34 8.84 2kvaA1 PHE 693 HA -0.03 0.22 0.76 -0.75 4.62 4.82 2kvaA1 PHE 693 HB2 -0.11 -0.04 0.16 -0.04 3.15 3.12 2kvaA1 PHE 693 HB3 -0.13 -0.04 -0.08 -0.04 3.06 2.77 2kvaA1 PHE 693 HD2 -0.63 0.01 -0.38 -0.04 7.28 6.24 2kvaA1 PHE 693 HE2 -1.55 0.02 -0.34 -0.04 7.38 5.48 2kvaA1 PHE 693 HZ -0.66 0.03 -0.17 -0.04 7.32 6.48 2kvaA1 LEU 694 H 0.08 0.86 0.50 -0.55 8.37 9.26 2kvaA1 LEU 694 HA 0.07 0.19 0.99 -0.75 4.35 4.85 2kvaA1 LEU 694 HB2 -0.07 -0.03 0.07 -0.04 1.64 1.57 2kvaA1 LEU 694 HB3 0.11 -0.02 -0.06 -0.04 1.64 1.63 2kvaA1 LEU 694 HG -0.09 0.07 -0.29 -0.04 1.64 1.30 2kvaA1 LEU 694 HD13 -0.14 0.00 -0.06 -0.04 0.93 0.69 2kvaA1 LEU 694 HD23 -0.03 -0.00 -0.12 -0.04 0.89 0.70 2kvaA1 CYS 695 H 0.10 0.26 -0.01 -0.55 8.50 8.31 2kvaA1 CYS 695 HA 0.19 0.17 0.85 -0.75 4.58 5.04 2kvaA1 CYS 695 HB2 0.09 -0.02 -0.21 -0.04 2.97 2.79 2kvaA1 CYS 695 HB3 0.08 0.05 -0.04 -0.04 2.97 3.03 2kvaA1 ASP 696 H 0.28 0.24 -0.29 -0.55 8.40 8.08 2kvaA1 ASP 696 HA 0.09 0.14 0.83 -0.75 4.63 4.94 2kvaA1 ASP 696 HB2 0.22 -0.01 -0.06 -0.04 2.71 2.82 2kvaA1 ASP 696 HB3 0.08 0.01 0.06 -0.04 2.70 2.81 2kvaA1 ARG 697 H 0.05 0.22 0.05 -0.55 8.46 8.23 2kvaA1 ARG 697 HA 0.03 0.03 0.36 -0.75 4.34 4.01 2kvaA1 ARG 697 HB2 0.01 -0.03 -0.04 -0.04 1.90 1.80 2kvaA1 ARG 697 HB3 -0.00 0.09 -0.02 -0.04 1.80 1.83 2kvaA1 ARG 697 HG2 -0.00 -0.02 -0.00 -0.04 1.67 1.61 2kvaA1 ARG 697 HG3 0.01 0.03 -0.06 -0.04 1.67 1.61 2kvaA1 ARG 697 HD2 0.01 -0.02 0.02 -0.04 3.22 3.20 2kvaA1 ARG 697 HD3 0.01 -0.01 -0.02 -0.04 3.22 3.15 2kvaA1 ASP 698 H 0.02 0.40 0.35 -0.55 8.40 8.62 2kvaA1 ASP 698 HA 0.05 0.14 0.81 -0.75 4.63 4.87 2kvaA1 ASP 698 HB2 0.02 -0.04 0.02 -0.04 2.71 2.66 2kvaA1 ASP 698 HB3 0.03 0.00 -0.02 -0.04 2.70 2.68 2kvaA1 ALA 699 H 0.07 0.32 0.17 -0.55 8.40 8.41 2kvaA1 ALA 699 HA 0.09 0.10 0.47 -0.75 4.34 4.26 2kvaA1 ALA 699 HB3 0.19 0.03 -0.23 -0.04 1.41 1.36 2kvaA1 GLY 700 H 0.18 0.14 0.08 -0.55 8.43 8.28 2kvaA1 GLY 700 HA2 0.14 0.30 0.98 -0.51 4.01 4.91 2kvaA1 GLY 700 HA3 0.17 0.00 0.46 -0.51 4.01 4.13 2kvaA1 VAL 701 H 0.29 0.19 0.19 -0.55 8.24 8.36 2kvaA1 VAL 701 HA 0.55 0.06 0.60 -0.75 4.13 4.59 2kvaA1 VAL 701 HB 0.35 0.10 0.14 -0.04 2.12 2.67 2kvaA1 VAL 701 HG13 0.32 -0.10 0.09 -0.04 0.97 1.24 2kvaA1 VAL 701 HG23 0.31 0.06 0.06 -0.04 0.95 1.34 2kvaA1 GLY 702 H 0.29 -0.12 -0.10 -0.55 8.43 7.96 2kvaA1 GLY 702 HA2 0.23 0.18 0.41 -0.51 4.01 4.32 2kvaA1 GLY 702 HA3 0.49 0.18 0.61 -0.51 4.01 4.78 2kvaA1 PHE 703 H 0.01 0.20 0.20 -0.55 8.34 8.20 2kvaA1 PHE 703 HA -0.46 0.27 0.95 -0.75 4.62 4.63 2kvaA1 PHE 703 HB2 -0.04 -0.04 0.04 -0.04 3.15 3.06 2kvaA1 PHE 703 HB3 -0.06 -0.05 0.15 -0.04 3.06 3.07 2kvaA1 PHE 703 HD2 -0.01 -0.08 -0.04 -0.04 7.28 7.11 2kvaA1 PHE 703 HE2 0.01 -0.09 0.12 -0.04 7.38 7.38 2kvaA1 PHE 703 HZ 0.01 -0.07 0.17 -0.04 7.32 7.39 2kvaA1 PRO 704 HA -0.37 0.14 0.56 -0.51 4.44 4.27 2kvaA1 PRO 704 HB2 -0.34 -0.00 -0.24 -0.04 2.28 1.66 2kvaA1 PRO 704 HB3 -0.38 0.00 -0.14 -0.04 2.02 1.47 2kvaA1 PRO 704 HG2 -0.70 0.05 -0.14 -0.04 2.03 1.20 2kvaA1 PRO 704 HG3 -0.83 0.04 -0.13 -0.04 2.03 1.06 2kvaA1 PRO 704 HD2 -1.33 0.12 0.20 -0.04 3.68 2.63 2kvaA1 PRO 704 HD3 -1.75 0.21 0.02 -0.04 3.65 2.08 2kvaA1 GLU 705 H 0.01 0.73 0.36 -0.55 8.60 9.15 2kvaA1 GLU 705 HA 0.12 0.17 0.98 -0.75 4.29 4.81 2kvaA1 GLU 705 HB2 0.12 0.02 0.12 -0.04 2.09 2.32 2kvaA1 GLU 705 HB3 0.15 0.02 0.10 -0.04 1.99 2.22 2kvaA1 GLU 705 HG2 0.39 0.04 -0.09 -0.04 2.34 2.64 2kvaA1 GLU 705 HG3 0.26 0.11 -0.22 -0.04 2.34 2.45 2kvaA1 TYR 706 H 0.23 0.18 0.14 -0.55 8.29 8.28 2kvaA1 TYR 706 HA -0.46 0.13 0.64 -0.75 4.56 4.11 2kvaA1 TYR 706 HB2 -0.00 0.00 -0.09 -0.04 3.06 2.93 2kvaA1 TYR 706 HB3 0.04 0.04 0.01 -0.04 2.98 3.03 2kvaA1 TYR 706 HD2 -0.73 0.05 -0.15 -0.04 7.15 6.28 2kvaA1 TYR 706 HE2 -0.18 0.08 -0.16 -0.04 6.85 6.55 2kvaA1 GLN 707 H -0.89 0.33 0.23 -0.55 8.47 7.60 2kvaA1 GLN 707 HA -0.29 0.14 0.59 -0.75 4.36 4.05 2kvaA1 GLN 707 HB2 -0.61 -0.05 0.33 -0.04 2.15 1.78 2kvaA1 GLN 707 HB3 -0.35 -0.01 0.10 -0.04 2.02 1.73 2kvaA1 GLN 707 HG2 -0.30 -0.02 -0.15 -0.04 2.40 1.89 2kvaA1 GLN 707 HG3 -0.28 -0.06 -0.18 -0.04 2.39 1.83 2kvaA1 GLN 707 HE21 -0.11 0.02 -0.05 -0.04 6.97 6.79 2kvaA1 GLN 707 HE22 -0.17 -0.03 -0.04 -0.04 7.69 7.41 2kvaA1 GLU 708 H -1.00 -0.01 0.16 -0.55 8.60 7.21 2kvaA1 GLU 708 HA -0.33 0.07 0.35 -0.75 4.29 3.61 2kvaA1 GLU 708 HB2 -0.13 -0.03 0.06 -0.04 2.09 1.95 2kvaA1 GLU 708 HB3 -0.18 0.30 0.08 -0.04 1.99 2.15 2kvaA1 GLU 708 HG2 -0.25 -0.10 -0.31 -0.04 2.34 1.64 2kvaA1 GLU 708 HG3 -0.19 -0.03 -0.23 -0.04 2.34 1.85 2kvaA1 GLU 709 H -0.49 -0.03 0.21 -0.55 8.60 7.74 2kvaA1 GLU 709 HA -0.22 0.04 0.51 -0.75 4.29 3.86 2kvaA1 GLU 709 HB2 -0.30 -0.07 0.39 -0.04 2.09 2.07 2kvaA1 GLU 709 HB3 -0.22 0.06 0.14 -0.04 1.99 1.93 2kvaA1 GLU 709 HG2 -0.17 0.03 0.04 -0.04 2.34 2.20 2kvaA1 GLU 709 HG3 -0.24 -0.08 0.09 -0.04 2.34 2.07 2kvaA1 ASP 710 H -0.20 0.28 0.29 -0.55 8.40 8.22 2kvaA1 ASP 710 HA -1.38 0.25 0.60 -0.75 4.63 3.35 2kvaA1 ASP 710 HB2 -0.29 0.04 0.05 -0.04 2.71 2.47 2kvaA1 ASP 710 HB3 0.02 -0.01 -0.10 -0.04 2.70 2.57 2kvaA1 ASN 711 H -0.26 -0.04 0.07 -0.55 8.53 7.75 2kvaA1 ASN 711 HA -0.20 0.11 0.34 -0.75 4.76 4.26 2kvaA1 ASN 711 HB2 -0.09 0.06 0.05 -0.04 2.88 2.86 2kvaA1 ASN 711 HB3 -0.12 0.00 0.12 -0.04 2.79 2.75 2kvaA1 ASN 711 HD21 -0.07 0.01 -0.03 -0.04 7.03 6.90 2kvaA1 ASN 711 HD22 -0.06 0.04 -0.03 -0.04 7.74 7.64 2kvaA1 SER 712 H -0.23 -0.01 -0.56 -0.55 8.46 7.12 2kvaA1 SER 712 HA 0.13 0.17 0.29 -0.75 4.49 4.32 2kvaA1 SER 712 HB2 0.15 0.03 -0.03 -0.04 3.95 4.07 2kvaA1 SER 712 HB3 0.11 0.21 0.02 -0.04 3.93 4.23 2kvaA1 THR 713 H -0.01 0.08 0.01 -0.55 8.28 7.80 2kvaA1 THR 713 HA 0.16 0.24 0.63 -0.75 4.39 4.66 2kvaA1 THR 713 HB -0.03 -0.07 0.09 -0.04 4.32 4.27 2kvaA1 THR 713 HG23 0.04 0.00 -0.23 -0.04 1.22 0.99 2kvaA1 TYR 714 H 0.41 0.61 0.30 -0.55 8.29 9.06 2kvaA1 TYR 714 HA -0.10 0.31 0.84 -0.75 4.56 4.85 2kvaA1 TYR 714 HB2 0.19 0.05 0.28 -0.04 3.06 3.54 2kvaA1 TYR 714 HB3 0.08 -0.05 0.01 -0.04 2.98 2.97 2kvaA1 TYR 714 HD2 0.11 0.08 0.02 -0.04 7.15 7.32 2kvaA1 TYR 714 HE2 -0.05 -0.01 -0.08 -0.04 6.85 6.67 2kvaA1 ASN 715 H -0.24 0.17 0.26 -0.55 8.53 8.18 2kvaA1 ASN 715 HA -0.04 0.42 0.95 -0.75 4.76 5.34 2kvaA1 ASN 715 HB2 -0.14 0.01 0.07 -0.04 2.88 2.78 2kvaA1 ASN 715 HB3 -0.24 -0.15 0.14 -0.04 2.79 2.50 2kvaA1 ASN 715 HD21 -0.10 0.00 -0.07 -0.04 7.03 6.82 2kvaA1 ASN 715 HD22 -0.09 -0.02 -0.03 -0.04 7.74 7.55 2kvaA1 PHE 716 H 0.05 0.68 0.43 -0.55 8.34 8.95 2kvaA1 PHE 716 HA -0.10 0.17 1.09 -0.75 4.62 5.03 2kvaA1 PHE 716 HB2 -0.03 -0.02 -0.08 -0.04 3.15 2.98 2kvaA1 PHE 716 HB3 -0.02 0.01 -0.15 -0.04 3.06 2.86 2kvaA1 PHE 716 HD2 -0.04 0.10 -0.45 -0.04 7.28 6.85 2kvaA1 PHE 716 HE2 -0.25 -0.02 -0.24 -0.04 7.38 6.83 2kvaA1 PHE 716 HZ -1.54 -0.03 -0.21 -0.04 7.32 5.50 2kvaA1 ARG 717 H 0.02 0.78 0.26 -0.55 8.46 8.98 2kvaA1 ARG 717 HA -0.14 0.14 0.67 -0.75 4.34 4.26 2kvaA1 ARG 717 HB2 -0.09 -0.02 -0.04 -0.04 1.90 1.71 2kvaA1 ARG 717 HB3 -0.01 -0.04 0.14 -0.04 1.80 1.84 2kvaA1 ARG 717 HG2 0.04 0.01 -0.05 -0.04 1.67 1.63 2kvaA1 ARG 717 HG3 -0.49 0.01 -0.12 -0.04 1.67 1.03 2kvaA1 ARG 717 HD2 -0.22 0.06 0.01 -0.04 3.22 3.03 2kvaA1 ARG 717 HD3 -0.09 -0.03 -0.05 -0.04 3.22 3.00 2kvaA1 TRP 718 H -0.09 0.58 0.30 -0.55 7.97 8.22 2kvaA1 TRP 718 HA -0.08 0.29 0.93 -0.75 4.62 5.01 2kvaA1 TRP 718 HB2 -0.24 -0.06 -0.32 -0.04 3.23 2.58 2kvaA1 TRP 718 HB3 -0.29 0.02 -0.09 -0.04 3.23 2.84 2kvaA1 TRP 718 HD1 0.20 -0.08 -0.71 -0.04 7.22 6.58 2kvaA1 TRP 718 HE1 0.08 0.67 0.14 -0.04 10.20 11.04 2kvaA1 TRP 718 HE3 -0.24 -0.06 -0.26 -0.04 7.59 6.99 2kvaA1 TRP 718 HZ2 -0.50 0.10 -0.14 -0.04 7.44 6.85 2kvaA1 TRP 718 HZ3 -0.23 -0.02 -0.31 -0.04 7.13 6.53 2kvaA1 TRP 718 HH2 -0.77 -0.06 -0.18 -0.04 7.19 6.13 2kvaA1 TYR 719 H 0.21 0.29 0.14 -0.55 8.29 8.38 2kvaA1 TYR 719 HA 0.24 0.47 1.14 -0.75 4.56 5.66 2kvaA1 TYR 719 HB2 0.13 -0.06 0.24 -0.04 3.06 3.33 2kvaA1 TYR 719 HB3 0.13 0.04 0.05 -0.04 2.98 3.16 2kvaA1 TYR 719 HD2 0.09 -0.00 -0.01 -0.04 7.15 7.19 2kvaA1 TYR 719 HE2 0.05 0.00 -0.06 -0.04 6.85 6.81 2kvaA1 THR 720 H 0.36 0.58 0.12 -0.55 8.28 8.80 2kvaA1 THR 720 HA 0.38 0.12 0.69 -0.75 4.39 4.83 2kvaA1 THR 720 HB 0.77 0.20 -0.29 -0.04 4.32 4.95 2kvaA1 THR 720 HG23 0.23 0.01 -0.22 -0.04 1.22 1.19 2kvaA1 SER 721 H 0.24 0.72 0.02 -0.55 8.46 8.90 2kvaA1 SER 721 HA 0.08 0.08 0.38 -0.75 4.49 4.28 2kvaA1 SER 721 HB2 0.06 0.14 0.01 -0.04 3.95 4.12 2kvaA1 SER 721 HB3 -0.04 0.02 0.03 -0.04 3.93 3.89 2kvaA1 TYR 722 H 0.31 0.13 -0.25 -0.55 8.29 7.92 2kvaA1 TYR 722 HA -0.02 0.17 0.33 -0.75 4.56 4.28 2kvaA1 TYR 722 HB2 -0.12 0.00 -0.04 -0.04 3.06 2.86 2kvaA1 TYR 722 HB3 -0.13 0.01 0.01 -0.04 2.98 2.83 2kvaA1 TYR 722 HD2 0.17 0.05 0.06 -0.04 7.15 7.39 2kvaA1 TYR 722 HE2 0.12 -0.05 -0.09 -0.04 6.85 6.79 2kvaA1 ALA 723 H 0.04 0.21 -0.79 -0.55 8.40 7.31 2kvaA1 ALA 723 HA -0.14 0.11 0.59 -0.75 4.34 4.15 2kvaA1 ALA 723 HB3 0.07 0.00 -0.14 -0.04 1.41 1.30 2kvaA1 CYS 724 H -0.07 0.42 -0.50 -0.55 8.50 7.80 2kvaA1 CYS 724 HA 0.08 0.15 0.90 -0.75 4.58 4.97 2kvaA1 CYS 724 HB2 0.04 0.18 0.18 -0.04 2.97 3.32 2kvaA1 CYS 724 HB3 0.07 -0.03 -0.01 -0.04 2.97 2.96 2kvaA1 PRO 725 HA 0.40 0.19 0.50 -0.51 4.44 5.03 2kvaA1 PRO 725 HB2 0.25 0.03 0.06 -0.04 2.28 2.58 2kvaA1 PRO 725 HB3 0.49 0.00 -0.02 -0.04 2.02 2.45 2kvaA1 PRO 725 HG2 0.23 0.03 0.06 -0.04 2.03 2.30 2kvaA1 PRO 725 HG3 0.46 0.02 0.00 -0.04 2.03 2.47 2kvaA1 PRO 725 HD2 0.15 0.07 0.15 -0.04 3.68 4.01 2kvaA1 PRO 725 HD3 0.20 0.29 0.15 -0.04 3.65 4.25