============================================================================= SHIFTS, version 4.1 [X.-P. Xu and D.A. Case, Mar. 2002] ============================================================================= shifts will be computed for atoms matching ::H* found 23 rings ring int. center anis. iso. PHE 6 1.000 8.983 -11.163 16.642 -99.200 -91.000 PHE 18 1.000 10.992 -15.120 -0.739 -99.200 -91.000 PHE 24 1.000 1.727 -17.181 5.165 -99.200 -91.000 PHE 26 1.000 -0.617 -13.881 2.707 -99.200 -91.000 TYR 37 0.840 -5.307 0.366 -2.954 -99.200 -91.000 TYR 44 0.840 -0.877 16.795 5.817 -99.200 -91.000 PHE 46 1.000 -1.756 10.958 4.674 -99.200 -91.000 HIS 47 0.900 -3.600 10.160 -4.029 -99.200 -91.000 TRP 76 1.040 5.913 18.073 1.919 -99.200 -91.000 TRP6 76 1.020 3.769 18.743 2.615 -99.200 -91.000 TYR 87 0.840 2.933 -12.752 7.120 -99.200 -91.000 TYR 88 0.840 5.676 -7.894 13.850 -99.200 -91.000 TYR 96 0.840 5.519 2.114 -0.965 -99.200 -91.000 TYR 102 0.840 8.776 15.036 7.358 -99.200 -91.000 PHE 116 1.000 -0.983 -4.502 2.964 -99.200 -91.000 PHE 126 1.000 -9.956 3.413 2.223 -99.200 -91.000 TYR 129 0.840 -1.398 9.504 9.061 -99.200 -91.000 TYR 137 0.840 3.453 10.791 7.288 -99.200 -91.000 PHE 139 1.000 -0.972 5.865 5.550 -99.200 -91.000 TRP 141 1.040 -4.261 -2.498 2.431 -99.200 -91.000 TRP6 141 1.020 -3.132 -1.144 0.863 -99.200 -91.000 TYR 142 0.840 -8.503 -2.233 9.384 -99.200 -91.000 TYR 145 0.840 -6.376 -9.969 -2.480 -99.200 -91.000 ============================================================================= Atom RingCur El P_anis Const RC pred Obs ============================================================================= 2kvaA11 GLU 578 HA -0.00 0.28 0.38 -0.75 4.29 4.20 2kvaA11 GLU 578 HB2 -0.02 -0.06 0.00 -0.04 2.09 1.97 2kvaA11 GLU 578 HB3 -0.03 -0.08 -0.12 -0.04 1.99 1.72 2kvaA11 GLU 578 HG2 -0.01 -0.06 0.03 -0.04 2.34 2.26 2kvaA11 GLU 578 HG3 0.01 0.12 0.19 -0.04 2.34 2.62 2kvaA11 ALA 579 H -0.02 0.33 -0.02 -0.55 8.40 8.14 2kvaA11 ALA 579 HA -0.02 0.19 0.93 -0.75 4.34 4.69 2kvaA11 ALA 579 HB3 -0.02 -0.03 0.15 -0.04 1.41 1.46 2kvaA11 GLU 580 H -0.03 0.44 -0.10 -0.55 8.60 8.36 2kvaA11 GLU 580 HA -0.07 0.18 0.86 -0.75 4.29 4.50 2kvaA11 GLU 580 HB2 -0.07 -0.04 -0.13 -0.04 2.09 1.81 2kvaA11 GLU 580 HB3 -0.08 0.02 -0.25 -0.04 1.99 1.64 2kvaA11 GLU 580 HG2 -0.03 0.12 -0.14 -0.04 2.34 2.25 2kvaA11 GLU 580 HG3 -0.03 -0.03 0.02 -0.04 2.34 2.26 2kvaA11 ALA 581 H -0.03 0.39 -0.16 -0.55 8.40 8.05 2kvaA11 ALA 581 HA -0.01 0.07 0.44 -0.75 4.34 4.08 2kvaA11 ALA 581 HB3 0.00 0.04 0.05 -0.04 1.41 1.46 2kvaA11 GLU 582 H -0.01 0.19 -0.03 -0.55 8.60 8.20 2kvaA11 GLU 582 HA 0.01 0.03 0.38 -0.75 4.29 3.95 2kvaA11 GLU 582 HB2 0.01 -0.02 -0.06 -0.04 2.09 1.99 2kvaA11 GLU 582 HB3 0.04 0.20 0.11 -0.04 1.99 2.29 2kvaA11 GLU 582 HG2 0.02 -0.01 -0.01 -0.04 2.34 2.30 2kvaA11 GLU 582 HG3 0.06 0.01 -0.16 -0.04 2.34 2.21 2kvaA11 PHE 583 H 0.10 0.81 0.18 -0.55 8.34 8.88 2kvaA11 PHE 583 HA -0.15 0.12 0.89 -0.75 4.62 4.73 2kvaA11 PHE 583 HB2 -0.08 -0.02 -0.02 -0.04 3.15 2.99 2kvaA11 PHE 583 HB3 -0.08 0.04 0.11 -0.04 3.06 3.09 2kvaA11 PHE 583 HD2 -0.15 -0.02 -0.08 -0.04 7.28 6.99 2kvaA11 PHE 583 HE2 -0.23 -0.07 -0.04 -0.04 7.38 7.01 2kvaA11 PHE 583 HZ -0.01 -0.07 0.02 -0.04 7.32 7.22 2kvaA11 LEU 584 H -0.81 0.12 0.15 -0.55 8.37 7.29 2kvaA11 LEU 584 HA -0.34 0.27 0.97 -0.75 4.35 4.49 2kvaA11 LEU 584 HB2 -0.48 -0.07 0.01 -0.04 1.64 1.06 2kvaA11 LEU 584 HB3 -0.31 0.06 -0.02 -0.04 1.64 1.32 2kvaA11 LEU 584 HG -0.18 0.07 -0.04 -0.04 1.64 1.46 2kvaA11 LEU 584 HD13 -0.21 0.00 -0.62 -0.04 0.93 0.06 2kvaA11 LEU 584 HD23 -0.20 -0.00 -0.17 -0.04 0.89 0.48 2kvaA11 SER 585 H -0.27 0.17 0.11 -0.55 8.46 7.92 2kvaA11 SER 585 HA -0.25 0.03 0.36 -0.75 4.49 3.88 2kvaA11 SER 585 HB2 -0.09 -0.07 0.06 -0.04 3.95 3.81 2kvaA11 SER 585 HB3 -0.04 0.07 0.02 -0.04 3.93 3.94 2kvaA11 ARG 586 H -0.03 0.09 0.19 -0.55 8.46 8.16 2kvaA11 ARG 586 HA -0.05 0.52 0.90 -0.75 4.34 4.96 2kvaA11 ARG 586 HB2 0.26 -0.04 0.10 -0.04 1.90 2.18 2kvaA11 ARG 586 HB3 0.11 -0.05 0.17 -0.04 1.80 1.98 2kvaA11 ARG 586 HG2 0.02 -0.01 -0.40 -0.04 1.67 1.24 2kvaA11 ARG 586 HG3 0.07 0.02 -0.22 -0.04 1.67 1.50 2kvaA11 ARG 586 HD2 0.08 -0.02 -0.08 -0.04 3.22 3.15 2kvaA11 ARG 586 HD3 0.06 -0.02 -0.06 -0.04 3.22 3.16 2kvaA11 THR 587 H 0.00 0.57 0.37 -0.55 8.28 8.68 2kvaA11 THR 587 HA -0.06 0.16 0.99 -0.75 4.39 4.73 2kvaA11 THR 587 HB -0.02 -0.03 0.04 -0.04 4.32 4.27 2kvaA11 THR 587 HG23 -0.21 -0.02 0.03 -0.04 1.22 0.98 2kvaA11 GLU 588 H -0.10 0.17 0.22 -0.55 8.60 8.35 2kvaA11 GLU 588 HA -0.09 0.30 1.21 -0.75 4.29 4.95 2kvaA11 GLU 588 HB2 -0.08 0.08 0.04 -0.04 2.09 2.09 2kvaA11 GLU 588 HB3 -0.06 -0.03 -0.01 -0.04 1.99 1.85 2kvaA11 GLU 588 HG2 -0.06 -0.04 0.15 -0.04 2.34 2.34 2kvaA11 GLU 588 HG3 -0.08 0.01 0.08 -0.04 2.34 2.32 2kvaA11 GLY 589 H -0.12 0.84 0.42 -0.55 8.43 9.02 2kvaA11 GLY 589 HA2 -0.24 0.15 1.06 -0.51 4.01 4.47 2kvaA11 GLY 589 HA3 -0.16 0.12 0.60 -0.51 4.01 4.06 2kvaA11 ASP 590 H 0.04 0.30 0.33 -0.55 8.40 8.52 2kvaA11 ASP 590 HA -0.03 0.21 0.78 -0.75 4.63 4.84 2kvaA11 ASP 590 HB2 -0.01 0.10 -0.19 -0.04 2.71 2.58 2kvaA11 ASP 590 HB3 0.04 0.02 -0.00 -0.04 2.70 2.72 2kvaA11 ASN 591 H 0.01 0.12 0.18 -0.55 8.53 8.30 2kvaA11 ASN 591 HA 0.01 0.02 0.36 -0.75 4.76 4.40 2kvaA11 ASN 591 HB2 0.04 0.14 -0.08 -0.04 2.88 2.95 2kvaA11 ASN 591 HB3 0.02 0.02 0.23 -0.04 2.79 3.02 2kvaA11 ASN 591 HD21 0.02 0.01 -0.02 -0.04 7.03 7.00 2kvaA11 ASN 591 HD22 0.03 0.03 -0.05 -0.04 7.74 7.71 2kvaA11 CYS 592 H -0.01 0.23 -0.15 -0.55 8.50 8.02 2kvaA11 CYS 592 HA -0.03 0.08 0.22 -0.75 4.58 4.09 2kvaA11 CYS 592 HB2 0.01 -0.07 -0.18 -0.04 2.97 2.69 2kvaA11 CYS 592 HB3 0.01 0.23 0.14 -0.04 2.97 3.31 2kvaA11 THR 593 H 0.01 0.29 -0.20 -0.55 8.28 7.82 2kvaA11 THR 593 HA 0.03 0.13 1.03 -0.75 4.39 4.83 2kvaA11 THR 593 HB 0.11 0.02 0.05 -0.04 4.32 4.46 2kvaA11 THR 593 HG23 0.03 -0.03 -0.27 -0.04 1.22 0.92 2kvaA11 VAL 594 H 0.07 0.82 0.33 -0.55 8.24 8.91 2kvaA11 VAL 594 HA -0.06 0.08 0.77 -0.75 4.13 4.15 2kvaA11 VAL 594 HB -0.04 0.02 -0.27 -0.04 2.12 1.78 2kvaA11 VAL 594 HG13 0.06 0.00 -0.09 -0.04 0.97 0.90 2kvaA11 VAL 594 HG23 0.02 0.01 -0.26 -0.04 0.95 0.68 2kvaA11 PHE 595 H -0.38 0.25 0.09 -0.55 8.34 7.74 2kvaA11 PHE 595 HA -0.05 0.29 0.97 -0.75 4.62 5.08 2kvaA11 PHE 595 HB2 -0.04 0.07 -0.03 -0.04 3.15 3.11 2kvaA11 PHE 595 HB3 -0.05 0.01 -0.08 -0.04 3.06 2.91 2kvaA11 PHE 595 HD2 -0.02 -0.02 -0.22 -0.04 7.28 6.99 2kvaA11 PHE 595 HE2 -0.01 -0.01 -0.00 -0.04 7.38 7.32 2kvaA11 PHE 595 HZ -0.01 0.01 0.02 -0.04 7.32 7.30 2kvaA11 ASP 596 H 0.14 0.92 0.26 -0.55 8.40 9.17 2kvaA11 ASP 596 HA 0.00 0.11 0.81 -0.75 4.63 4.80 2kvaA11 ASP 596 HB2 0.16 -0.06 0.18 -0.04 2.71 2.95 2kvaA11 ASP 596 HB3 0.06 -0.12 0.04 -0.04 2.70 2.63 2kvaA11 SER 597 H 0.03 0.25 0.20 -0.55 8.46 8.39 2kvaA11 SER 597 HA 0.11 0.15 0.44 -0.75 4.49 4.43 2kvaA11 SER 597 HB2 0.03 -0.04 0.16 -0.04 3.95 4.06 2kvaA11 SER 597 HB3 0.06 0.06 0.07 -0.04 3.93 4.09 2kvaA11 GLN 598 H 0.02 0.06 -0.00 -0.55 8.47 7.99 2kvaA11 GLN 598 HA 0.01 0.23 0.51 -0.75 4.36 4.35 2kvaA11 GLN 598 HB2 -0.02 0.01 0.12 -0.04 2.15 2.21 2kvaA11 GLN 598 HB3 -0.01 0.04 0.10 -0.04 2.02 2.11 2kvaA11 GLN 598 HG2 -0.04 0.03 0.07 -0.04 2.40 2.42 2kvaA11 GLN 598 HG3 -0.02 -0.05 0.08 -0.04 2.39 2.36 2kvaA11 GLN 598 HE21 -0.13 0.07 -0.02 -0.04 6.97 6.85 2kvaA11 GLN 598 HE22 -0.10 0.14 0.08 -0.04 7.69 7.78 2kvaA11 ALA 599 H 0.03 -0.06 -0.35 -0.55 8.40 7.47 2kvaA11 ALA 599 HA 0.01 0.18 0.83 -0.75 4.34 4.60 2kvaA11 ALA 599 HB3 0.01 -0.00 -0.00 -0.04 1.41 1.37 2kvaA11 GLY 600 H 0.07 0.18 -0.24 -0.55 8.43 7.88 2kvaA11 GLY 600 HA2 0.05 0.02 0.32 -0.51 4.01 3.89 2kvaA11 GLY 600 HA3 0.04 0.07 0.49 -0.51 4.01 4.11 2kvaA11 PHE 601 H 0.15 0.17 0.06 -0.55 8.34 8.16 2kvaA11 PHE 601 HA -0.12 0.22 0.68 -0.75 4.62 4.64 2kvaA11 PHE 601 HB2 -0.07 0.11 -0.20 -0.04 3.15 2.94 2kvaA11 PHE 601 HB3 -0.09 -0.14 -0.01 -0.04 3.06 2.78 2kvaA11 PHE 601 HD2 -0.35 -0.03 -0.18 -0.04 7.28 6.67 2kvaA11 PHE 601 HE2 -0.85 -0.02 -0.12 -0.04 7.38 6.35 2kvaA11 PHE 601 HZ -0.58 0.04 -0.10 -0.04 7.32 6.64 2kvaA11 SER 602 H -1.00 0.26 0.18 -0.55 8.46 7.36 2kvaA11 SER 602 HA -0.16 0.21 0.89 -0.75 4.49 4.68 2kvaA11 SER 602 HB2 -0.22 -0.01 0.01 -0.04 3.95 3.69 2kvaA11 SER 602 HB3 -0.09 0.02 0.02 -0.04 3.93 3.85 2kvaA11 PHE 603 H -0.04 0.81 0.36 -0.55 8.34 8.92 2kvaA11 PHE 603 HA -0.12 0.13 0.59 -0.75 4.62 4.47 2kvaA11 PHE 603 HB2 -0.12 -0.07 -0.03 -0.04 3.15 2.89 2kvaA11 PHE 603 HB3 -0.04 0.02 -0.12 -0.04 3.06 2.88 2kvaA11 PHE 603 HD2 -0.13 -0.08 -0.02 -0.04 7.28 7.00 2kvaA11 PHE 603 HE2 0.10 -0.01 -0.21 -0.04 7.38 7.22 2kvaA11 PHE 603 HZ 0.27 -0.06 -0.51 -0.04 7.32 6.99 2kvaA11 ASP 604 H 0.17 0.30 0.17 -0.55 8.40 8.48 2kvaA11 ASP 604 HA 0.04 0.20 0.92 -0.75 4.63 5.04 2kvaA11 ASP 604 HB2 0.03 0.03 0.14 -0.04 2.71 2.86 2kvaA11 ASP 604 HB3 0.04 0.02 0.01 -0.04 2.70 2.73 2kvaA11 LEU 605 H -0.01 0.59 0.20 -0.55 8.37 8.60 2kvaA11 LEU 605 HA -0.12 0.24 0.89 -0.75 4.35 4.61 2kvaA11 LEU 605 HB2 -0.07 0.06 -0.04 -0.04 1.64 1.54 2kvaA11 LEU 605 HB3 -0.08 -0.02 0.07 -0.04 1.64 1.57 2kvaA11 LEU 605 HG -0.06 -0.08 -0.42 -0.04 1.64 1.05 2kvaA11 LEU 605 HD13 -0.24 0.00 -0.20 -0.04 0.93 0.46 2kvaA11 LEU 605 HD23 -0.16 0.04 -0.20 -0.04 0.89 0.53 2kvaA11 THR 606 H -0.01 0.12 -0.12 -0.55 8.28 7.71 2kvaA11 THR 606 HA 0.01 0.07 0.41 -0.75 4.39 4.12 2kvaA11 THR 606 HB 0.01 0.03 0.09 -0.04 4.32 4.42 2kvaA11 THR 606 HG23 0.02 -0.00 -0.07 -0.04 1.22 1.12 2kvaA11 PRO 607 HA 0.02 0.11 0.39 -0.51 4.44 4.45 2kvaA11 PRO 607 HB2 0.01 0.05 -0.08 -0.04 2.28 2.22 2kvaA11 PRO 607 HB3 0.06 0.02 0.09 -0.04 2.02 2.15 2kvaA11 PRO 607 HG2 0.09 0.08 0.02 -0.04 2.03 2.17 2kvaA11 PRO 607 HG3 0.05 0.02 0.03 -0.04 2.03 2.09 2kvaA11 PRO 607 HD2 -0.06 0.15 -0.09 -0.04 3.68 3.64 2kvaA11 PRO 607 HD3 0.01 0.02 0.06 -0.04 3.65 3.70 2kvaA11 LEU 608 H -0.13 0.13 -0.82 -0.55 8.37 7.01 2kvaA11 LEU 608 HA -0.07 0.08 0.53 -0.75 4.35 4.14 2kvaA11 LEU 608 HB2 -0.51 -0.10 0.04 -0.04 1.64 1.03 2kvaA11 LEU 608 HB3 -0.08 0.11 0.02 -0.04 1.64 1.65 2kvaA11 LEU 608 HG -0.22 0.04 0.12 -0.04 1.64 1.54 2kvaA11 LEU 608 HD13 0.05 0.00 0.00 -0.04 0.93 0.94 2kvaA11 LEU 608 HD23 0.09 -0.02 -0.02 -0.04 0.89 0.91 2kvaA11 THR 609 H 0.04 0.27 -0.24 -0.55 8.28 7.79 2kvaA11 THR 609 HA 0.24 -0.16 0.56 -0.75 4.39 4.28 2kvaA11 THR 609 HB 0.06 0.19 0.19 -0.04 4.32 4.73 2kvaA11 THR 609 HG23 0.12 0.02 0.01 -0.04 1.22 1.33 2kvaA11 LYS 610 H 0.27 0.06 0.27 -0.55 8.42 8.46 2kvaA11 LYS 610 HA 0.04 0.24 0.93 -0.75 4.32 4.78 2kvaA11 LYS 610 HB2 -0.08 -0.06 0.11 -0.04 1.87 1.81 2kvaA11 LYS 610 HB3 -0.09 -0.15 0.09 -0.04 1.79 1.60 2kvaA11 LYS 610 HG2 -0.04 0.08 -0.11 -0.04 1.46 1.35 2kvaA11 LYS 610 HG3 -0.05 0.12 -0.07 -0.04 1.46 1.41 2kvaA11 LYS 610 HD2 -1.02 0.04 -0.14 -0.04 1.69 0.53 2kvaA11 LYS 610 HD3 -0.27 -0.04 -0.03 -0.04 1.68 1.30 2kvaA11 LYS 610 HE2 -0.11 -0.02 -0.01 -0.04 2.99 2.81 2kvaA11 LYS 610 HE3 -0.37 0.07 -0.02 -0.04 2.99 2.63 2kvaA11 LYS 611 H 0.01 0.20 0.18 -0.55 8.42 8.26 2kvaA11 LYS 611 HA 0.03 0.20 0.58 -0.75 4.32 4.38 2kvaA11 LYS 611 HB2 0.01 0.03 0.08 -0.04 1.87 1.95 2kvaA11 LYS 611 HB3 0.02 0.03 0.10 -0.04 1.79 1.89 2kvaA11 LYS 611 HG2 0.00 -0.04 0.12 -0.04 1.46 1.49 2kvaA11 LYS 611 HG3 -0.00 0.05 -0.16 -0.04 1.46 1.30 2kvaA11 LYS 611 HD2 0.00 0.01 -0.02 -0.04 1.69 1.64 2kvaA11 LYS 611 HD3 0.01 0.01 0.02 -0.04 1.68 1.68 2kvaA11 LYS 611 HE2 -0.00 -0.00 0.01 -0.04 2.99 2.96 2kvaA11 LYS 611 HE3 -0.00 0.01 -0.02 -0.04 2.99 2.93 2kvaA11 ASP 612 H -0.02 0.00 -0.09 -0.55 8.40 7.74 2kvaA11 ASP 612 HA -0.01 0.15 0.68 -0.75 4.63 4.70 2kvaA11 ASP 612 HB2 -0.05 -0.00 0.05 -0.04 2.71 2.67 2kvaA11 ASP 612 HB3 -0.02 0.06 0.10 -0.04 2.70 2.79 2kvaA11 ALA 613 H -0.00 -0.11 -0.44 -0.55 8.40 7.29 2kvaA11 ALA 613 HA 0.13 -0.01 0.38 -0.75 4.34 4.08 2kvaA11 ALA 613 HB3 0.09 0.08 -0.03 -0.04 1.41 1.51 2kvaA11 TYR 614 H 0.31 0.71 0.40 -0.55 8.29 9.16 2kvaA11 TYR 614 HA -0.05 0.09 0.77 -0.75 4.56 4.62 2kvaA11 TYR 614 HB2 -0.13 0.10 0.12 -0.04 3.06 3.10 2kvaA11 TYR 614 HB3 -0.38 0.01 0.03 -0.04 2.98 2.59 2kvaA11 TYR 614 HD2 -0.15 -0.01 0.13 -0.04 7.15 7.08 2kvaA11 TYR 614 HE2 0.02 0.03 0.11 -0.04 6.85 6.97 2kvaA11 LYS 615 H -0.00 0.20 0.24 -0.55 8.42 8.31 2kvaA11 LYS 615 HA -0.26 0.41 1.15 -0.75 4.32 4.87 2kvaA11 LYS 615 HB2 -0.30 -0.03 -0.09 -0.04 1.87 1.41 2kvaA11 LYS 615 HB3 -0.28 0.06 -0.08 -0.04 1.79 1.45 2kvaA11 LYS 615 HG2 0.06 -0.03 0.12 -0.04 1.46 1.57 2kvaA11 LYS 615 HG3 0.02 -0.03 -0.07 -0.04 1.46 1.34 2kvaA11 LYS 615 HD2 0.05 -0.03 0.02 -0.04 1.69 1.69 2kvaA11 LYS 615 HD3 0.12 0.01 -0.05 -0.04 1.68 1.72 2kvaA11 LYS 615 HE2 0.09 -0.02 -0.37 -0.04 2.99 2.65 2kvaA11 LYS 615 HE3 0.01 -0.12 0.13 -0.04 2.99 2.97 2kvaA11 VAL 616 H -0.11 0.84 0.33 -0.55 8.24 8.75 2kvaA11 VAL 616 HA 0.07 0.22 0.97 -0.75 4.13 4.63 2kvaA11 VAL 616 HB 0.41 -0.15 0.18 -0.04 2.12 2.51 2kvaA11 VAL 616 HG13 0.36 0.00 -0.07 -0.04 0.97 1.22 2kvaA11 VAL 616 HG23 0.06 0.06 -0.18 -0.04 0.95 0.85 2kvaA11 GLU 617 H 0.20 0.24 0.17 -0.55 8.60 8.67 2kvaA11 GLU 617 HA 0.12 0.17 1.19 -0.75 4.29 5.01 2kvaA11 GLU 617 HB2 0.11 -0.02 0.11 -0.04 2.09 2.25 2kvaA11 GLU 617 HB3 0.07 0.09 0.02 -0.04 1.99 2.14 2kvaA11 GLU 617 HG2 0.02 0.02 -0.14 -0.04 2.34 2.21 2kvaA11 GLU 617 HG3 0.06 -0.04 -0.30 -0.04 2.34 2.02 2kvaA11 THR 618 H 0.14 0.72 0.45 -0.55 8.28 9.05 2kvaA11 THR 618 HA 0.15 0.20 0.80 -0.75 4.39 4.79 2kvaA11 THR 618 HB 0.21 -0.11 0.22 -0.04 4.32 4.60 2kvaA11 THR 618 HG23 0.44 0.03 -0.15 -0.04 1.22 1.49 2kvaA11 ASP 619 H 0.08 0.14 0.18 -0.55 8.40 8.25 2kvaA11 ASP 619 HA 0.02 0.20 0.54 -0.75 4.63 4.63 2kvaA11 ASP 619 HB2 0.01 -0.04 0.14 -0.04 2.71 2.78 2kvaA11 ASP 619 HB3 -0.00 0.04 0.06 -0.04 2.70 2.76 2kvaA11 LYS 620 H -0.01 0.01 -0.01 -0.55 8.42 7.86 2kvaA11 LYS 620 HA -0.21 0.12 0.68 -0.75 4.32 4.15 2kvaA11 LYS 620 HB2 -0.30 0.01 0.13 -0.04 1.87 1.66 2kvaA11 LYS 620 HB3 -0.84 -0.01 0.05 -0.04 1.79 0.94 2kvaA11 LYS 620 HG2 -0.14 0.03 0.01 -0.04 1.46 1.33 2kvaA11 LYS 620 HG3 -0.06 -0.05 0.03 -0.04 1.46 1.35 2kvaA11 LYS 620 HD2 -0.01 0.03 0.01 -0.04 1.69 1.67 2kvaA11 LYS 620 HD3 0.03 0.03 0.02 -0.04 1.68 1.72 2kvaA11 LYS 620 HE2 -0.27 -0.03 -0.01 -0.04 2.99 2.65 2kvaA11 LYS 620 HE3 -0.09 -0.00 0.00 -0.04 2.99 2.87 2kvaA11 TYR 621 H 0.00 0.05 -0.02 -0.55 8.29 7.77 2kvaA11 TYR 621 HA -0.09 0.18 1.02 -0.75 4.56 4.93 2kvaA11 TYR 621 HB2 -0.64 -0.02 -0.14 -0.04 3.06 2.22 2kvaA11 TYR 621 HB3 -0.51 0.05 -0.12 -0.04 2.98 2.35 2kvaA11 TYR 621 HD2 0.18 0.02 -0.13 -0.04 7.15 7.18 2kvaA11 TYR 621 HE2 0.19 0.03 -0.07 -0.04 6.85 6.96 2kvaA11 GLU 622 H -0.10 0.69 0.32 -0.55 8.60 8.97 2kvaA11 GLU 622 HA -0.04 0.25 0.87 -0.75 4.29 4.62 2kvaA11 GLU 622 HB2 -0.11 0.03 0.01 -0.04 2.09 1.98 2kvaA11 GLU 622 HB3 0.00 0.02 0.08 -0.04 1.99 2.04 2kvaA11 GLU 622 HG2 0.02 0.14 0.04 -0.04 2.34 2.50 2kvaA11 GLU 622 HG3 0.08 -0.10 0.07 -0.04 2.34 2.34 2kvaA11 PHE 623 H 0.14 0.89 0.37 -0.55 8.34 9.19 2kvaA11 PHE 623 HA -0.04 0.17 0.89 -0.75 4.62 4.89 2kvaA11 PHE 623 HB2 -0.00 -0.03 0.06 -0.04 3.15 3.14 2kvaA11 PHE 623 HB3 -0.11 0.03 -0.14 -0.04 3.06 2.80 2kvaA11 PHE 623 HD2 -0.01 0.10 -0.15 -0.04 7.28 7.18 2kvaA11 PHE 623 HE2 -0.14 0.02 -0.17 -0.04 7.38 7.04 2kvaA11 PHE 623 HZ -0.12 0.01 -0.13 -0.04 7.32 7.04 2kvaA11 HIS 624 H 0.10 0.87 0.40 -0.55 8.41 9.24 2kvaA11 HIS 624 HA 0.01 0.48 1.32 -0.75 4.63 5.68 2kvaA11 HIS 624 HB2 -0.03 -0.05 0.11 -0.04 3.26 3.25 2kvaA11 HIS 624 HB3 -0.01 0.08 -0.07 -0.04 3.20 3.15 2kvaA11 HIS 624 HD2 -0.03 0.02 -0.14 -0.04 6.97 6.78 2kvaA11 HIS 624 HE1 0.00 -0.01 -0.08 -0.04 7.75 7.62 2kvaA11 ILE 625 H 0.04 0.66 0.25 -0.55 8.25 8.65 2kvaA11 ILE 625 HA -0.11 0.26 0.86 -0.75 4.18 4.44 2kvaA11 ILE 625 HB -0.04 -0.04 -0.15 -0.04 1.89 1.62 2kvaA11 ILE 625 HG12 -0.29 0.03 -0.33 -0.04 1.49 0.86 2kvaA11 ILE 625 HG23 0.08 0.00 -0.18 -0.04 0.93 0.79 2kvaA11 ILE 625 HG13 -0.48 -0.03 -0.43 -0.04 1.21 0.23 2kvaA11 ILE 625 HD13 -0.31 0.03 -0.22 -0.04 0.88 0.34 2kvaA11 ASN 626 H 0.03 0.53 0.15 -0.55 8.53 8.69 2kvaA11 ASN 626 HA 0.43 0.04 0.68 -0.75 4.76 5.16 2kvaA11 ASN 626 HB2 0.14 -0.05 -0.19 -0.04 2.88 2.74 2kvaA11 ASN 626 HB3 0.13 0.17 -0.30 -0.04 2.79 2.74 2kvaA11 ASN 626 HD21 0.11 -0.03 0.10 -0.04 7.03 7.17 2kvaA11 ASN 626 HD22 0.10 0.53 0.07 -0.04 7.74 8.40 2kvaA11 VAL 627 H 0.31 0.11 0.12 -0.55 8.24 8.23 2kvaA11 VAL 627 HA -0.03 0.04 0.27 -0.75 4.13 3.66 2kvaA11 VAL 627 HB 0.09 -0.01 -0.02 -0.04 2.12 2.14 2kvaA11 VAL 627 HG13 -0.04 0.00 -0.09 -0.04 0.97 0.80 2kvaA11 VAL 627 HG23 0.07 -0.02 -0.18 -0.04 0.95 0.78 2kvaA11 CYS 628 H 0.14 0.16 -0.18 -0.55 8.50 8.08 2kvaA11 CYS 628 HA 0.06 0.18 0.73 -0.75 4.58 4.79 2kvaA11 CYS 628 HB2 0.05 0.02 -0.07 -0.04 2.97 2.93 2kvaA11 CYS 628 HB3 0.02 -0.08 -0.03 -0.04 2.97 2.84 2kvaA11 GLY 629 H 0.12 0.10 -0.17 -0.55 8.43 7.94 2kvaA11 GLY 629 HA2 0.09 -0.08 0.13 -0.51 4.01 3.65 2kvaA11 GLY 629 HA3 0.08 0.16 0.25 -0.51 4.01 3.99 2kvaA11 PRO 630 HA 0.01 0.13 0.29 -0.51 4.44 4.36 2kvaA11 PRO 630 HB2 0.01 0.09 -0.21 -0.04 2.28 2.12 2kvaA11 PRO 630 HB3 0.02 -0.07 -0.29 -0.04 2.02 1.64 2kvaA11 PRO 630 HG2 0.02 0.03 -0.08 -0.04 2.03 1.97 2kvaA11 PRO 630 HG3 0.02 0.05 0.02 -0.04 2.03 2.09 2kvaA11 PRO 630 HD2 0.05 0.16 0.16 -0.04 3.68 4.01 2kvaA11 PRO 630 HD3 0.05 -0.01 0.13 -0.04 3.65 3.78 2kvaA11 VAL 631 H -0.03 0.71 0.21 -0.55 8.24 8.58 2kvaA11 VAL 631 HA 0.03 0.14 0.74 -0.75 4.13 4.29 2kvaA11 VAL 631 HB 0.03 0.05 -0.34 -0.04 2.12 1.81 2kvaA11 VAL 631 HG13 -0.09 0.01 -0.51 -0.04 0.97 0.33 2kvaA11 VAL 631 HG23 -0.03 0.06 -0.45 -0.04 0.95 0.49 2kvaA11 SER 632 H 0.00 0.16 -0.20 -0.55 8.46 7.88 2kvaA11 SER 632 HA -0.04 0.12 0.80 -0.75 4.49 4.62 2kvaA11 SER 632 HB2 -0.01 0.16 0.10 -0.04 3.95 4.16 2kvaA11 SER 632 HB3 -0.02 -0.00 0.13 -0.04 3.93 3.99 2kvaA11 VAL 633 H -0.08 0.39 0.13 -0.55 8.24 8.12 2kvaA11 VAL 633 HA -0.24 0.11 0.59 -0.75 4.13 3.83 2kvaA11 VAL 633 HB -0.15 0.01 -0.18 -0.04 2.12 1.75 2kvaA11 VAL 633 HG13 -0.59 0.07 0.00 -0.04 0.97 0.41 2kvaA11 VAL 633 HG23 -0.25 -0.03 -0.50 -0.04 0.95 0.13 2kvaA11 GLY 634 H -0.15 0.15 0.10 -0.55 8.43 7.98 2kvaA11 GLY 634 HA2 -0.07 0.16 0.59 -0.51 4.01 4.18 2kvaA11 GLY 634 HA3 -0.07 0.03 0.34 -0.51 4.01 3.80 2kvaA11 ALA 635 H -0.11 0.03 -0.05 -0.55 8.40 7.72 2kvaA11 ALA 635 HA -0.08 0.18 0.47 -0.75 4.34 4.16 2kvaA11 ALA 635 HB3 -0.09 0.00 0.03 -0.04 1.41 1.32 2kvaA11 CYS 636 H -0.09 0.23 -0.73 -0.55 8.50 7.36 2kvaA11 CYS 636 HA -0.06 0.20 0.81 -0.75 4.58 4.77 2kvaA11 CYS 636 HB2 -0.09 0.02 -0.19 -0.04 2.97 2.67 2kvaA11 CYS 636 HB3 -0.05 0.02 -0.06 -0.04 2.97 2.83 2kvaA11 PRO 637 HA -0.03 0.17 0.41 -0.51 4.44 4.48 2kvaA11 PRO 637 HB2 -0.01 -0.07 -0.02 -0.04 2.28 2.13 2kvaA11 PRO 637 HB3 -0.02 0.08 0.08 -0.04 2.02 2.12 2kvaA11 PRO 637 HG2 -0.01 -0.08 0.07 -0.04 2.03 1.97 2kvaA11 PRO 637 HG3 -0.01 0.07 0.05 -0.04 2.03 2.10 2kvaA11 PRO 637 HD2 -0.03 0.05 0.16 -0.04 3.68 3.82 2kvaA11 PRO 637 HD3 -0.04 0.19 0.12 -0.04 3.65 3.88 2kvaA11 PRO 638 HA -0.02 0.26 0.36 -0.51 4.44 4.53 2kvaA11 PRO 638 HB2 -0.01 0.01 0.18 -0.04 2.28 2.42 2kvaA11 PRO 638 HB3 -0.02 0.06 0.14 -0.04 2.02 2.17 2kvaA11 PRO 638 HG2 -0.01 0.01 -0.02 -0.04 2.03 1.97 2kvaA11 PRO 638 HG3 -0.01 0.04 0.08 -0.04 2.03 2.10 2kvaA11 PRO 638 HD2 -0.02 0.04 0.18 -0.04 3.68 3.84 2kvaA11 PRO 638 HD3 -0.02 0.22 0.23 -0.04 3.65 4.03 2kvaA11 ASP 639 H -0.01 0.12 -1.04 -0.55 8.40 6.92 2kvaA11 ASP 639 HA 0.01 0.20 0.72 -0.75 4.63 4.81 2kvaA11 ASP 639 HB2 0.01 0.04 -0.16 -0.04 2.71 2.56 2kvaA11 ASP 639 HB3 0.01 -0.01 -0.04 -0.04 2.70 2.61 2kvaA11 SER 640 H -0.01 0.48 0.13 -0.55 8.46 8.52 2kvaA11 SER 640 HA -0.00 0.08 1.09 -0.75 4.49 4.91 2kvaA11 SER 640 HB2 -0.03 0.02 0.02 -0.04 3.95 3.92 2kvaA11 SER 640 HB3 -0.01 -0.04 0.07 -0.04 3.93 3.90 2kvaA11 GLY 641 H -0.08 0.55 0.26 -0.55 8.43 8.62 2kvaA11 GLY 641 HA2 -0.14 0.09 0.94 -0.51 4.01 4.39 2kvaA11 GLY 641 HA3 -0.22 0.07 0.21 -0.51 4.01 3.56 2kvaA11 ALA 642 H -0.23 0.25 0.02 -0.55 8.40 7.90 2kvaA11 ALA 642 HA -0.23 0.37 0.57 -0.75 4.34 4.30 2kvaA11 ALA 642 HB3 -0.30 0.00 -0.13 -0.04 1.41 0.94 2kvaA11 CYS 643 H -0.03 0.82 0.25 -0.55 8.50 8.99 2kvaA11 CYS 643 HA 0.00 0.01 0.99 -0.75 4.58 4.82 2kvaA11 CYS 643 HB2 -0.03 -0.01 -0.22 -0.04 2.97 2.67 2kvaA11 CYS 643 HB3 -0.01 0.03 -0.06 -0.04 2.97 2.90 2kvaA11 GLN 644 H 0.04 0.67 0.34 -0.55 8.47 8.98 2kvaA11 GLN 644 HA -0.09 0.34 1.28 -0.75 4.36 5.14 2kvaA11 GLN 644 HB2 -0.48 -0.03 -0.11 -0.04 2.15 1.49 2kvaA11 GLN 644 HB3 -0.20 -0.05 -0.09 -0.04 2.02 1.65 2kvaA11 GLN 644 HG2 0.02 0.09 0.04 -0.04 2.40 2.50 2kvaA11 GLN 644 HG3 0.31 -0.06 -0.03 -0.04 2.39 2.57 2kvaA11 GLN 644 HE21 -0.32 0.01 -0.12 -0.04 6.97 6.50 2kvaA11 GLN 644 HE22 -0.22 0.02 -0.13 -0.04 7.69 7.32 2kvaA11 VAL 645 H -0.03 0.83 0.38 -0.55 8.24 8.88 2kvaA11 VAL 645 HA -0.06 0.24 1.10 -0.75 4.13 4.65 2kvaA11 VAL 645 HB 0.05 -0.03 0.12 -0.04 2.12 2.22 2kvaA11 VAL 645 HG13 -0.02 0.00 -0.08 -0.04 0.97 0.83 2kvaA11 VAL 645 HG23 -0.02 0.04 -0.20 -0.04 0.95 0.73 2kvaA11 SER 646 H -0.04 0.98 0.32 -0.55 8.46 9.17 2kvaA11 SER 646 HA 0.21 0.10 0.85 -0.75 4.49 4.89 2kvaA11 SER 646 HB2 0.60 0.08 0.09 -0.04 3.95 4.67 2kvaA11 SER 646 HB3 0.02 -0.21 0.18 -0.04 3.93 3.88 2kvaA11 ARG 647 H -0.06 0.82 0.46 -0.55 8.46 9.14 2kvaA11 ARG 647 HA -0.02 0.20 0.85 -0.75 4.34 4.62 2kvaA11 ARG 647 HB2 -0.04 0.20 -0.04 -0.04 1.90 1.98 2kvaA11 ARG 647 HB3 -0.02 -0.02 0.04 -0.04 1.80 1.77 2kvaA11 ARG 647 HG2 0.00 -0.01 -0.14 -0.04 1.67 1.48 2kvaA11 ARG 647 HG3 -0.01 -0.04 -0.28 -0.04 1.67 1.31 2kvaA11 ARG 647 HD2 0.02 -0.08 -0.18 -0.04 3.22 2.94 2kvaA11 ARG 647 HD3 0.01 0.23 -0.25 -0.04 3.22 3.17 2kvaA11 SER 648 H -0.08 0.18 0.29 -0.55 8.46 8.30 2kvaA11 SER 648 HA -0.03 0.20 0.64 -0.75 4.49 4.55 2kvaA11 SER 648 HB2 -0.08 -0.07 0.19 -0.04 3.95 3.94 2kvaA11 SER 648 HB3 -0.04 0.03 0.08 -0.04 3.93 3.96 2kvaA11 ASP 649 H 0.01 -0.01 0.00 -0.55 8.40 7.85 2kvaA11 ASP 649 HA 0.01 0.25 0.73 -0.75 4.63 4.87 2kvaA11 ASP 649 HB2 0.15 -0.08 0.06 -0.04 2.71 2.80 2kvaA11 ASP 649 HB3 0.07 0.05 0.08 -0.04 2.70 2.87 2kvaA11 ARG 650 H -0.02 -0.04 -0.60 -0.55 8.46 7.24 2kvaA11 ARG 650 HA -0.06 0.49 0.28 -0.75 4.34 4.30 2kvaA11 ARG 650 HB2 -0.05 0.11 -0.15 -0.04 1.90 1.77 2kvaA11 ARG 650 HB3 -0.06 -0.04 0.18 -0.04 1.80 1.84 2kvaA11 ARG 650 HG2 -0.03 0.04 0.02 -0.04 1.67 1.65 2kvaA11 ARG 650 HG3 -0.03 0.04 -0.32 -0.04 1.67 1.31 2kvaA11 ARG 650 HD2 -0.02 0.01 -0.03 -0.04 3.22 3.13 2kvaA11 ARG 650 HD3 -0.03 -0.01 -0.10 -0.04 3.22 3.05 2kvaA11 LYS 651 H -0.15 -0.16 -0.47 -0.55 8.42 7.08 2kvaA11 LYS 651 HA -0.35 0.23 0.79 -0.75 4.32 4.24 2kvaA11 LYS 651 HB2 -0.74 -0.11 -0.03 -0.04 1.87 0.94 2kvaA11 LYS 651 HB3 -0.96 0.04 0.07 -0.04 1.79 0.89 2kvaA11 LYS 651 HG2 -0.18 0.05 -0.01 -0.04 1.46 1.28 2kvaA11 LYS 651 HG3 -0.11 0.13 -0.14 -0.04 1.46 1.30 2kvaA11 LYS 651 HD2 0.22 -0.07 -0.02 -0.04 1.69 1.77 2kvaA11 LYS 651 HD3 0.03 0.02 -0.00 -0.04 1.68 1.68 2kvaA11 LYS 651 HE2 0.01 0.02 0.01 -0.04 2.99 2.98 2kvaA11 LYS 651 HE3 0.05 0.02 0.01 -0.04 2.99 3.03 2kvaA11 SER 652 H -0.73 0.23 0.23 -0.55 8.46 7.65 2kvaA11 SER 652 HA -0.41 0.29 1.19 -0.75 4.49 4.80 2kvaA11 SER 652 HB2 -0.16 0.01 0.01 -0.04 3.95 3.76 2kvaA11 SER 652 HB3 -0.20 -0.02 -0.11 -0.04 3.93 3.57 2kvaA11 TRP 653 H 0.05 0.66 0.37 -0.55 7.97 8.50 2kvaA11 TRP 653 HA -0.01 0.10 0.81 -0.75 4.62 4.76 2kvaA11 TRP 653 HB2 -0.09 -0.05 -0.03 -0.04 3.23 3.02 2kvaA11 TRP 653 HB3 0.01 0.05 0.01 -0.04 3.23 3.26 2kvaA11 TRP 653 HD1 0.02 0.03 0.02 -0.04 7.22 7.25 2kvaA11 TRP 653 HE1 -0.01 0.01 -0.04 -0.04 10.20 10.12 2kvaA11 TRP 653 HE3 -0.14 0.02 -0.13 -0.04 7.59 7.30 2kvaA11 TRP 653 HZ2 0.01 0.02 -0.07 -0.04 7.44 7.37 2kvaA11 TRP 653 HZ3 0.19 -0.06 -0.15 -0.04 7.13 7.07 2kvaA11 TRP 653 HH2 0.13 -0.06 -0.07 -0.04 7.19 7.15 2kvaA11 ASN 654 H 0.20 0.19 0.22 -0.55 8.53 8.59 2kvaA11 ASN 654 HA 0.04 0.13 0.64 -0.75 4.76 4.82 2kvaA11 ASN 654 HB2 0.05 0.04 0.14 -0.04 2.88 3.08 2kvaA11 ASN 654 HB3 0.09 -0.02 0.22 -0.04 2.79 3.04 2kvaA11 ASN 654 HD21 0.02 0.00 -0.04 -0.04 7.03 6.97 2kvaA11 ASN 654 HD22 0.02 0.01 0.01 -0.04 7.74 7.74 2kvaA11 LEU 655 H 0.01 0.67 0.40 -0.55 8.37 8.90 2kvaA11 LEU 655 HA 0.04 0.06 0.48 -0.75 4.35 4.18 2kvaA11 LEU 655 HB2 -0.05 0.01 -0.33 -0.04 1.64 1.24 2kvaA11 LEU 655 HB3 -0.03 -0.02 -0.08 -0.04 1.64 1.48 2kvaA11 LEU 655 HG -0.07 0.02 -0.17 -0.04 1.64 1.37 2kvaA11 LEU 655 HD13 -0.02 0.01 -0.23 -0.04 0.93 0.65 2kvaA11 LEU 655 HD23 -0.32 -0.00 -0.21 -0.04 0.89 0.31 2kvaA11 GLY 656 H 0.02 0.13 -0.14 -0.55 8.43 7.89 2kvaA11 GLY 656 HA2 0.09 0.04 -0.32 -0.51 4.01 3.30 2kvaA11 GLY 656 HA3 0.15 0.09 0.26 -0.51 4.01 4.00 2kvaA11 ARG 657 H 0.09 0.59 0.15 -0.55 8.46 8.74 2kvaA11 ARG 657 HA 0.04 -0.03 0.72 -0.75 4.34 4.32 2kvaA11 ARG 657 HB2 0.05 0.06 0.16 -0.04 1.90 2.14 2kvaA11 ARG 657 HB3 0.06 0.00 0.11 -0.04 1.80 1.93 2kvaA11 ARG 657 HG2 0.05 0.09 0.06 -0.04 1.67 1.82 2kvaA11 ARG 657 HG3 0.03 0.07 0.16 -0.04 1.67 1.89 2kvaA11 ARG 657 HD2 0.03 -0.01 0.05 -0.04 3.22 3.25 2kvaA11 ARG 657 HD3 0.03 -0.03 0.03 -0.04 3.22 3.21 2kvaA11 SER 658 H 0.06 0.55 0.20 -0.55 8.46 8.73 2kvaA11 SER 658 HA 0.27 0.12 0.23 -0.75 4.49 4.35 2kvaA11 SER 658 HB2 0.06 0.01 -0.01 -0.04 3.95 3.97 2kvaA11 SER 658 HB3 0.10 -0.14 -0.40 -0.04 3.93 3.44 2kvaA11 ASN 659 H 0.35 0.35 0.22 -0.55 8.53 8.91 2kvaA11 ASN 659 HA 0.02 0.03 0.49 -0.75 4.76 4.55 2kvaA11 ASN 659 HB2 -0.06 -0.11 0.16 -0.04 2.88 2.84 2kvaA11 ASN 659 HB3 0.02 0.17 0.06 -0.04 2.79 3.00 2kvaA11 ASN 659 HD21 -0.56 0.37 0.30 -0.04 7.03 7.10 2kvaA11 ASN 659 HD22 -0.50 -0.15 0.16 -0.04 7.74 7.21 2kvaA11 ALA 660 H -0.03 0.18 0.13 -0.55 8.40 8.14 2kvaA11 ALA 660 HA -0.09 0.33 0.89 -0.75 4.34 4.72 2kvaA11 ALA 660 HB3 -0.01 -0.02 0.16 -0.04 1.41 1.50 2kvaA11 LYS 661 H -0.17 0.19 -0.52 -0.55 8.42 7.37 2kvaA11 LYS 661 HA -0.10 0.36 0.89 -0.75 4.32 4.72 2kvaA11 LYS 661 HB2 -0.14 0.03 0.20 -0.04 1.87 1.91 2kvaA11 LYS 661 HB3 -0.11 -0.00 0.07 -0.04 1.79 1.70 2kvaA11 LYS 661 HG2 -0.06 -0.03 0.05 -0.04 1.46 1.38 2kvaA11 LYS 661 HG3 -0.07 0.21 0.11 -0.04 1.46 1.67 2kvaA11 LYS 661 HD2 -0.05 -0.14 -0.08 -0.04 1.69 1.38 2kvaA11 LYS 661 HD3 -0.05 -0.03 0.06 -0.04 1.68 1.61 2kvaA11 LYS 661 HE2 -0.03 0.03 0.02 -0.04 2.99 2.97 2kvaA11 LYS 661 HE3 -0.03 0.06 -0.00 -0.04 2.99 2.98 2kvaA11 LEU 662 H -0.11 0.26 0.05 -0.55 8.37 8.02 2kvaA11 LEU 662 HA -0.22 0.18 0.88 -0.75 4.35 4.43 2kvaA11 LEU 662 HB2 -0.10 0.08 -0.21 -0.04 1.64 1.37 2kvaA11 LEU 662 HB3 -0.15 0.02 -0.22 -0.04 1.64 1.26 2kvaA11 LEU 662 HG -0.13 -0.04 -0.36 -0.04 1.64 1.06 2kvaA11 LEU 662 HD13 -0.44 0.00 -0.18 -0.04 0.93 0.27 2kvaA11 LEU 662 HD23 -0.22 -0.00 -0.38 -0.04 0.89 0.25 2kvaA11 SER 663 H -0.17 0.76 0.41 -0.55 8.46 8.91 2kvaA11 SER 663 HA -0.05 0.40 1.26 -0.75 4.49 5.35 2kvaA11 SER 663 HB2 -0.08 0.04 0.14 -0.04 3.95 4.00 2kvaA11 SER 663 HB3 -0.03 -0.05 -0.02 -0.04 3.93 3.79 2kvaA11 TYR 664 H 0.07 0.62 0.33 -0.55 8.29 8.77 2kvaA11 TYR 664 HA -0.01 0.16 1.06 -0.75 4.56 5.02 2kvaA11 TYR 664 HB2 0.05 -0.02 -0.20 -0.04 3.06 2.86 2kvaA11 TYR 664 HB3 -0.00 -0.07 0.06 -0.04 2.98 2.92 2kvaA11 TYR 664 HD2 0.02 -0.08 -0.22 -0.04 7.15 6.83 2kvaA11 TYR 664 HE2 -0.19 0.02 -0.27 -0.04 6.85 6.36 2kvaA11 TYR 665 H -0.17 0.64 0.19 -0.55 8.29 8.40 2kvaA11 TYR 665 HA -0.24 0.16 0.68 -0.75 4.56 4.40 2kvaA11 TYR 665 HB2 -0.13 0.08 0.07 -0.04 3.06 3.04 2kvaA11 TYR 665 HB3 -0.21 -0.12 0.17 -0.04 2.98 2.78 2kvaA11 TYR 665 HD2 -0.06 -0.00 0.05 -0.04 7.15 7.10 2kvaA11 TYR 665 HE2 0.16 0.02 0.02 -0.04 6.85 7.01 2kvaA11 ASP 666 H -0.93 0.14 0.12 -0.55 8.40 7.18 2kvaA11 ASP 666 HA -0.51 0.05 0.30 -0.75 4.63 3.72 2kvaA11 ASP 666 HB2 -0.21 -0.04 0.04 -0.04 2.71 2.45 2kvaA11 ASP 666 HB3 -0.25 0.07 0.02 -0.04 2.70 2.51 2kvaA11 GLY 667 H -0.27 -0.11 -0.35 -0.55 8.43 7.16 2kvaA11 GLY 667 HA2 -0.55 0.14 0.06 -0.51 4.01 3.14 2kvaA11 GLY 667 HA3 -0.08 0.08 0.53 -0.51 4.01 4.03 2kvaA11 MET 668 H -0.30 0.01 -0.10 -0.55 8.47 7.53 2kvaA11 MET 668 HA 0.12 0.37 0.99 -0.75 4.52 5.25 2kvaA11 MET 668 HB2 0.06 -0.15 0.08 -0.04 2.15 2.09 2kvaA11 MET 668 HB3 0.05 0.11 -0.00 -0.04 2.03 2.15 2kvaA11 MET 668 HG2 0.08 0.15 -0.02 -0.04 2.63 2.79 2kvaA11 MET 668 HG3 0.06 -0.15 -0.30 -0.04 2.56 2.12 2kvaA11 MET 668 HE3 0.10 -0.02 -0.03 -0.04 2.10 2.11 2kvaA11 ILE 669 H 0.18 0.33 0.18 -0.55 8.25 8.40 2kvaA11 ILE 669 HA 0.14 0.16 0.87 -0.75 4.18 4.60 2kvaA11 ILE 669 HB -0.16 -0.05 0.12 -0.04 1.89 1.76 2kvaA11 ILE 669 HG12 0.17 0.01 -0.08 -0.04 1.49 1.54 2kvaA11 ILE 669 HG23 -1.12 0.00 -0.39 -0.04 0.93 -0.62 2kvaA11 ILE 669 HG13 0.09 -0.01 -0.12 -0.04 1.21 1.13 2kvaA11 ILE 669 HD13 -0.53 -0.01 -0.21 -0.04 0.88 0.09 2kvaA11 GLN 670 H -0.13 0.94 0.39 -0.55 8.47 9.12 2kvaA11 GLN 670 HA -0.18 0.44 1.25 -0.75 4.36 5.11 2kvaA11 GLN 670 HB2 -0.10 -0.08 0.03 -0.04 2.15 1.95 2kvaA11 GLN 670 HB3 -0.10 0.02 -0.06 -0.04 2.02 1.83 2kvaA11 GLN 670 HG2 -0.09 0.03 -0.19 -0.04 2.40 2.11 2kvaA11 GLN 670 HG3 -0.08 0.07 -0.31 -0.04 2.39 2.03 2kvaA11 GLN 670 HE21 -0.30 -0.03 -0.08 -0.04 6.97 6.51 2kvaA11 GLN 670 HE22 -0.15 0.04 -0.13 -0.04 7.69 7.42 2kvaA11 LEU 671 H -0.21 0.69 0.30 -0.55 8.37 8.61 2kvaA11 LEU 671 HA -0.32 0.18 0.91 -0.75 4.35 4.36 2kvaA11 LEU 671 HB2 -0.54 -0.03 0.02 -0.04 1.64 1.04 2kvaA11 LEU 671 HB3 -0.09 -0.11 0.14 -0.04 1.64 1.53 2kvaA11 LEU 671 HG -0.39 -0.03 -0.01 -0.04 1.64 1.16 2kvaA11 LEU 671 HD13 -0.22 0.00 -0.08 -0.04 0.93 0.59 2kvaA11 LEU 671 HD23 -0.32 0.08 -0.03 -0.04 0.89 0.58 2kvaA11 THR 672 H -0.26 0.43 0.23 -0.55 8.28 8.14 2kvaA11 THR 672 HA -0.04 0.29 1.16 -0.75 4.39 5.04 2kvaA11 THR 672 HB -0.11 0.01 0.10 -0.04 4.32 4.28 2kvaA11 THR 672 HG23 -0.01 -0.00 -0.24 -0.04 1.22 0.92 2kvaA11 TYR 673 H 0.11 0.87 0.33 -0.55 8.29 9.06 2kvaA11 TYR 673 HA -0.00 0.15 1.02 -0.75 4.56 4.97 2kvaA11 TYR 673 HB2 0.02 -0.03 0.12 -0.04 3.06 3.13 2kvaA11 TYR 673 HB3 0.02 -0.04 -0.12 -0.04 2.98 2.79 2kvaA11 TYR 673 HD2 0.00 0.10 -0.18 -0.04 7.15 7.04 2kvaA11 TYR 673 HE2 -0.00 -0.15 -0.00 -0.04 6.85 6.65 2kvaA11 ARG 674 H 0.06 0.22 0.15 -0.55 8.46 8.34 2kvaA11 ARG 674 HA 0.06 0.20 0.86 -0.75 4.34 4.71 2kvaA11 ARG 674 HB2 0.02 0.04 0.04 -0.04 1.90 1.96 2kvaA11 ARG 674 HB3 0.02 -0.05 0.13 -0.04 1.80 1.86 2kvaA11 ARG 674 HG2 0.01 0.01 -0.10 -0.04 1.67 1.55 2kvaA11 ARG 674 HG3 -0.01 0.03 -0.19 -0.04 1.67 1.46 2kvaA11 ARG 674 HD2 -0.02 -0.01 -0.05 -0.04 3.22 3.11 2kvaA11 ARG 674 HD3 -0.01 0.01 -0.01 -0.04 3.22 3.17 2kvaA11 ASP 675 H 0.03 0.20 0.11 -0.55 8.40 8.20 2kvaA11 ASP 675 HA 0.03 0.07 0.34 -0.75 4.63 4.31 2kvaA11 ASP 675 HB2 0.05 0.11 0.10 -0.04 2.71 2.92 2kvaA11 ASP 675 HB3 0.04 0.01 0.25 -0.04 2.70 2.95 2kvaA11 GLY 676 H 0.05 0.36 -0.25 -0.55 8.43 8.05 2kvaA11 GLY 676 HA2 0.07 -0.07 0.05 -0.51 4.01 3.54 2kvaA11 GLY 676 HA3 0.07 0.16 0.03 -0.51 4.01 3.76 2kvaA11 THR 677 H 0.13 0.80 0.31 -0.55 8.28 8.97 2kvaA11 THR 677 HA 0.10 0.11 0.51 -0.75 4.39 4.36 2kvaA11 THR 677 HB 0.30 -0.04 0.18 -0.04 4.32 4.72 2kvaA11 THR 677 HG23 0.19 0.07 0.05 -0.04 1.22 1.49 2kvaA11 PRO 678 HA -0.10 0.38 0.53 -0.51 4.44 4.74 2kvaA11 PRO 678 HB2 0.03 0.04 -0.06 -0.04 2.28 2.25 2kvaA11 PRO 678 HB3 -0.02 -0.19 -0.26 -0.04 2.02 1.51 2kvaA11 PRO 678 HG2 0.03 0.04 0.00 -0.04 2.03 2.07 2kvaA11 PRO 678 HG3 0.01 0.07 -0.12 -0.04 2.03 1.96 2kvaA11 PRO 678 HD2 0.08 0.07 0.21 -0.04 3.68 4.00 2kvaA11 PRO 678 HD3 0.06 0.25 0.28 -0.04 3.65 4.20 2kvaA11 TYR 679 H -0.25 -0.04 0.33 -0.55 8.29 7.78 2kvaA11 TYR 679 HA 0.00 0.12 0.42 -0.75 4.56 4.35 2kvaA11 TYR 679 HB2 -0.07 -0.02 0.11 -0.04 3.06 3.04 2kvaA11 TYR 679 HB3 -0.05 0.17 -0.09 -0.04 2.98 2.97 2kvaA11 TYR 679 HD2 -0.07 0.07 -0.30 -0.04 7.15 6.81 2kvaA11 TYR 679 HE2 -0.03 0.16 0.06 -0.04 6.85 7.00 2kvaA11 ASN 680 H -0.26 -0.09 0.27 -0.55 8.53 7.90 2kvaA11 ASN 680 HA 0.06 0.15 0.38 -0.75 4.76 4.59 2kvaA11 ASN 680 HB2 -0.23 0.05 0.10 -0.04 2.88 2.76 2kvaA11 ASN 680 HB3 -0.12 -0.10 0.18 -0.04 2.79 2.70 2kvaA11 ASN 680 HD21 -0.03 -0.00 -0.07 -0.04 7.03 6.88 2kvaA11 ASN 680 HD22 -0.06 -0.00 -0.05 -0.04 7.74 7.58 2kvaA11 ASN 681 H -0.04 -0.04 0.08 -0.55 8.53 7.99 2kvaA11 ASN 681 HA 0.00 0.30 0.86 -0.75 4.76 5.17 2kvaA11 ASN 681 HB2 -0.01 -0.03 0.08 -0.04 2.88 2.88 2kvaA11 ASN 681 HB3 -0.02 0.08 -0.08 -0.04 2.79 2.73 2kvaA11 ASN 681 HD21 -0.02 0.18 -0.34 -0.04 7.03 6.82 2kvaA11 ASN 681 HD22 -0.01 0.05 -0.09 -0.04 7.74 7.65 2kvaA11 GLU 682 H 0.01 0.19 0.13 -0.55 8.60 8.39 2kvaA11 GLU 682 HA 0.02 0.16 0.38 -0.75 4.29 4.09 2kvaA11 GLU 682 HB2 0.01 -0.03 0.09 -0.04 2.09 2.12 2kvaA11 GLU 682 HB3 0.01 0.06 0.05 -0.04 1.99 2.07 2kvaA11 GLU 682 HG2 0.01 0.06 0.03 -0.04 2.34 2.41 2kvaA11 GLU 682 HG3 0.01 -0.04 0.09 -0.04 2.34 2.36 2kvaA11 LYS 683 H -0.00 -0.01 -0.27 -0.55 8.42 7.59 2kvaA11 LYS 683 HA 0.00 0.16 0.32 -0.75 4.32 4.05 2kvaA11 LYS 683 HB2 -0.01 -0.05 -0.05 -0.04 1.87 1.73 2kvaA11 LYS 683 HB3 -0.00 0.08 0.10 -0.04 1.79 1.93 2kvaA11 LYS 683 HG2 -0.00 0.03 -0.00 -0.04 1.46 1.44 2kvaA11 LYS 683 HG3 0.00 0.05 -0.03 -0.04 1.46 1.44 2kvaA11 LYS 683 HD2 0.00 -0.18 -0.03 -0.04 1.69 1.44 2kvaA11 LYS 683 HD3 -0.00 -0.01 0.01 -0.04 1.68 1.63 2kvaA11 LYS 683 HE2 0.00 -0.02 0.00 -0.04 2.99 2.94 2kvaA11 LYS 683 HE3 -0.00 0.03 -0.01 -0.04 2.99 2.97 2kvaA11 ARG 684 H 0.00 0.15 -0.91 -0.55 8.46 7.15 2kvaA11 ARG 684 HA -0.01 -0.05 0.27 -0.75 4.34 3.80 2kvaA11 ARG 684 HB2 0.01 0.16 -0.03 -0.04 1.90 2.00 2kvaA11 ARG 684 HB3 0.01 -0.02 -0.02 -0.04 1.80 1.73 2kvaA11 ARG 684 HG2 0.02 -0.01 -0.06 -0.04 1.67 1.58 2kvaA11 ARG 684 HG3 0.02 0.08 -0.14 -0.04 1.67 1.59 2kvaA11 ARG 684 HD2 0.02 -0.00 -0.04 -0.04 3.22 3.15 2kvaA11 ARG 684 HD3 0.02 -0.01 -0.02 -0.04 3.22 3.17 2kvaA11 THR 685 H -0.05 -0.00 0.07 -0.55 8.28 7.75 2kvaA11 THR 685 HA -0.04 0.36 0.91 -0.75 4.39 4.86 2kvaA11 THR 685 HB -0.09 -0.26 0.15 -0.04 4.32 4.08 2kvaA11 THR 685 HG23 -0.10 0.02 -0.23 -0.04 1.22 0.87 2kvaA11 PRO 686 HA -0.03 0.16 0.29 -0.51 4.44 4.34 2kvaA11 PRO 686 HB2 0.01 -0.17 0.11 -0.04 2.28 2.18 2kvaA11 PRO 686 HB3 0.02 0.37 0.02 -0.04 2.02 2.39 2kvaA11 PRO 686 HG2 0.00 -0.01 0.09 -0.04 2.03 2.08 2kvaA11 PRO 686 HG3 0.00 0.08 0.01 -0.04 2.03 2.08 2kvaA11 PRO 686 HD2 -0.02 0.05 0.20 -0.04 3.68 3.87 2kvaA11 PRO 686 HD3 -0.02 0.33 0.02 -0.04 3.65 3.94 2kvaA11 ARG 687 H -0.08 0.24 -0.14 -0.55 8.46 7.93 2kvaA11 ARG 687 HA -0.05 0.08 0.43 -0.75 4.34 4.05 2kvaA11 ARG 687 HB2 0.01 0.14 0.23 -0.04 1.90 2.24 2kvaA11 ARG 687 HB3 -0.32 -0.06 0.11 -0.04 1.80 1.50 2kvaA11 ARG 687 HG2 0.21 0.08 -0.20 -0.04 1.67 1.72 2kvaA11 ARG 687 HG3 0.42 -0.05 0.07 -0.04 1.67 2.07 2kvaA11 ARG 687 HD2 0.09 0.18 0.06 -0.04 3.22 3.50 2kvaA11 ARG 687 HD3 0.09 -0.19 -0.05 -0.04 3.22 3.03 2kvaA11 ALA 688 H 0.08 0.20 0.27 -0.55 8.40 8.41 2kvaA11 ALA 688 HA 0.10 0.43 1.18 -0.75 4.34 5.30 2kvaA11 ALA 688 HB3 0.05 -0.03 -0.04 -0.04 1.41 1.35 2kvaA11 THR 689 H 0.16 0.74 0.38 -0.55 8.28 9.02 2kvaA11 THR 689 HA 0.29 0.13 1.02 -0.75 4.39 5.07 2kvaA11 THR 689 HB 0.21 0.00 0.15 -0.04 4.32 4.64 2kvaA11 THR 689 HG23 0.35 -0.00 -0.19 -0.04 1.22 1.33 2kvaA11 LEU 690 H 0.22 0.57 0.17 -0.55 8.37 8.78 2kvaA11 LEU 690 HA 0.09 0.50 1.36 -0.75 4.35 5.55 2kvaA11 LEU 690 HB2 0.04 -0.04 -0.16 -0.04 1.64 1.44 2kvaA11 LEU 690 HB3 0.06 -0.05 0.02 -0.04 1.64 1.62 2kvaA11 LEU 690 HG -0.03 0.11 -0.20 -0.04 1.64 1.49 2kvaA11 LEU 690 HD13 -0.08 0.00 -0.15 -0.04 0.93 0.66 2kvaA11 LEU 690 HD23 -0.03 -0.02 -0.32 -0.04 0.89 0.48 2kvaA11 ILE 691 H 0.09 0.79 0.34 -0.55 8.25 8.93 2kvaA11 ILE 691 HA 0.32 0.01 0.93 -0.75 4.18 4.69 2kvaA11 ILE 691 HB 0.20 -0.04 0.07 -0.04 1.89 2.08 2kvaA11 ILE 691 HG12 0.30 0.02 -0.17 -0.04 1.49 1.61 2kvaA11 ILE 691 HG23 0.57 0.00 -0.23 -0.04 0.93 1.23 2kvaA11 ILE 691 HG13 0.18 -0.03 -0.22 -0.04 1.21 1.10 2kvaA11 ILE 691 HD13 0.38 0.02 -0.25 -0.04 0.88 0.99 2kvaA11 THR 692 H 0.20 0.89 0.43 -0.55 8.28 9.24 2kvaA11 THR 692 HA 0.06 0.23 1.05 -0.75 4.39 4.97 2kvaA11 THR 692 HB 0.04 -0.00 0.21 -0.04 4.32 4.53 2kvaA11 THR 692 HG23 0.00 0.01 -0.12 -0.04 1.22 1.08 2kvaA11 PHE 693 H 0.20 0.91 0.30 -0.55 8.34 9.19 2kvaA11 PHE 693 HA -0.00 0.23 0.87 -0.75 4.62 4.96 2kvaA11 PHE 693 HB2 -0.09 -0.03 0.34 -0.04 3.15 3.33 2kvaA11 PHE 693 HB3 -0.10 -0.00 -0.01 -0.04 3.06 2.91 2kvaA11 PHE 693 HD2 -0.31 -0.07 -0.34 -0.04 7.28 6.52 2kvaA11 PHE 693 HE2 -0.78 -0.01 -0.17 -0.04 7.38 6.38 2kvaA11 PHE 693 HZ -1.47 0.02 -0.14 -0.04 7.32 5.68 2kvaA11 LEU 694 H 0.01 0.89 0.50 -0.55 8.37 9.22 2kvaA11 LEU 694 HA 0.11 0.19 1.01 -0.75 4.35 4.91 2kvaA11 LEU 694 HB2 -0.10 0.07 0.09 -0.04 1.64 1.65 2kvaA11 LEU 694 HB3 0.17 -0.10 0.11 -0.04 1.64 1.78 2kvaA11 LEU 694 HG 0.06 -0.01 -0.02 -0.04 1.64 1.63 2kvaA11 LEU 694 HD13 0.04 0.00 -0.10 -0.04 0.93 0.83 2kvaA11 LEU 694 HD23 -0.19 0.00 -0.11 -0.04 0.89 0.56 2kvaA11 CYS 695 H 0.15 0.20 0.12 -0.55 8.50 8.42 2kvaA11 CYS 695 HA 0.16 0.44 0.90 -0.75 4.58 5.33 2kvaA11 CYS 695 HB2 0.14 0.02 -0.22 -0.04 2.97 2.87 2kvaA11 CYS 695 HB3 0.13 -0.00 0.01 -0.04 2.97 3.07 2kvaA11 ASP 696 H 0.28 0.04 -0.48 -0.55 8.40 7.69 2kvaA11 ASP 696 HA 0.12 0.05 0.54 -0.75 4.63 4.58 2kvaA11 ASP 696 HB2 0.21 -0.03 0.04 -0.04 2.71 2.89 2kvaA11 ASP 696 HB3 0.44 0.02 0.09 -0.04 2.70 3.20 2kvaA11 ARG 697 H 0.06 0.12 0.09 -0.55 8.46 8.18 2kvaA11 ARG 697 HA 0.02 -0.05 0.34 -0.75 4.34 3.90 2kvaA11 ARG 697 HB2 -0.06 -0.04 -0.09 -0.04 1.90 1.67 2kvaA11 ARG 697 HB3 -0.10 0.28 0.18 -0.04 1.80 2.12 2kvaA11 ARG 697 HG2 -0.01 0.01 -0.50 -0.04 1.67 1.12 2kvaA11 ARG 697 HG3 -0.02 -0.02 -0.08 -0.04 1.67 1.50 2kvaA11 ARG 697 HD2 -0.06 0.01 -0.08 -0.04 3.22 3.04 2kvaA11 ARG 697 HD3 -0.09 -0.03 -0.06 -0.04 3.22 3.01 2kvaA11 ASP 698 H 0.03 0.12 0.04 -0.55 8.40 8.04 2kvaA11 ASP 698 HA 0.07 0.11 0.49 -0.75 4.63 4.54 2kvaA11 ASP 698 HB2 0.02 0.01 0.18 -0.04 2.71 2.88 2kvaA11 ASP 698 HB3 0.03 -0.05 0.05 -0.04 2.70 2.69 2kvaA11 ALA 699 H 0.10 0.27 0.03 -0.55 8.40 8.24 2kvaA11 ALA 699 HA 0.03 0.20 0.75 -0.75 4.34 4.58 2kvaA11 ALA 699 HB3 0.08 0.07 0.06 -0.04 1.41 1.58 2kvaA11 GLY 700 H 0.06 0.03 -0.26 -0.55 8.43 7.72 2kvaA11 GLY 700 HA2 0.05 0.07 0.31 -0.51 4.01 3.93 2kvaA11 GLY 700 HA3 0.08 0.14 0.69 -0.51 4.01 4.41 2kvaA11 VAL 701 H 0.16 0.24 0.22 -0.55 8.24 8.31 2kvaA11 VAL 701 HA 0.51 0.05 0.34 -0.75 4.13 4.27 2kvaA11 VAL 701 HB 0.22 0.04 0.13 -0.04 2.12 2.46 2kvaA11 VAL 701 HG13 0.34 0.00 -0.06 -0.04 0.97 1.21 2kvaA11 VAL 701 HG23 0.25 -0.01 0.03 -0.04 0.95 1.19 2kvaA11 GLY 702 H 0.16 0.10 -0.21 -0.55 8.43 7.94 2kvaA11 GLY 702 HA2 0.10 0.41 0.33 -0.51 4.01 4.35 2kvaA11 GLY 702 HA3 0.31 0.18 0.82 -0.51 4.01 4.81 2kvaA11 PHE 703 H -0.06 0.37 0.20 -0.55 8.34 8.29 2kvaA11 PHE 703 HA -0.51 0.27 1.01 -0.75 4.62 4.64 2kvaA11 PHE 703 HB2 -0.09 -0.02 0.02 -0.04 3.15 3.03 2kvaA11 PHE 703 HB3 -0.07 -0.04 0.15 -0.04 3.06 3.06 2kvaA11 PHE 703 HD2 -0.03 -0.06 -0.06 -0.04 7.28 7.10 2kvaA11 PHE 703 HE2 0.00 -0.04 0.08 -0.04 7.38 7.38 2kvaA11 PHE 703 HZ 0.01 -0.08 0.18 -0.04 7.32 7.40 2kvaA11 PRO 704 HA -0.23 0.16 0.58 -0.51 4.44 4.44 2kvaA11 PRO 704 HB2 -0.19 -0.02 -0.26 -0.04 2.28 1.77 2kvaA11 PRO 704 HB3 -0.20 0.01 -0.18 -0.04 2.02 1.61 2kvaA11 PRO 704 HG2 -0.60 0.02 -0.13 -0.04 2.03 1.28 2kvaA11 PRO 704 HG3 -1.08 0.05 -0.12 -0.04 2.03 0.84 2kvaA11 PRO 704 HD2 -1.59 0.14 0.19 -0.04 3.68 2.37 2kvaA11 PRO 704 HD3 -1.28 0.23 0.13 -0.04 3.65 2.69 2kvaA11 GLU 705 H 0.08 0.60 0.19 -0.55 8.60 8.92 2kvaA11 GLU 705 HA 0.14 0.12 0.89 -0.75 4.29 4.69 2kvaA11 GLU 705 HB2 0.21 0.10 0.21 -0.04 2.09 2.57 2kvaA11 GLU 705 HB3 0.14 0.08 -0.01 -0.04 1.99 2.16 2kvaA11 GLU 705 HG2 0.40 0.02 -0.23 -0.04 2.34 2.48 2kvaA11 GLU 705 HG3 0.26 -0.02 -0.00 -0.04 2.34 2.53 2kvaA11 TYR 706 H 0.18 0.15 0.08 -0.55 8.29 8.16 2kvaA11 TYR 706 HA -0.85 0.17 0.67 -0.75 4.56 3.80 2kvaA11 TYR 706 HB2 -0.64 0.00 -0.05 -0.04 3.06 2.34 2kvaA11 TYR 706 HB3 -0.18 0.04 -0.04 -0.04 2.98 2.77 2kvaA11 TYR 706 HD2 -0.73 0.16 -0.09 -0.04 7.15 6.45 2kvaA11 TYR 706 HE2 -0.08 0.02 -0.10 -0.04 6.85 6.65 2kvaA11 GLN 707 H -0.74 0.37 0.23 -0.55 8.47 7.78 2kvaA11 GLN 707 HA -0.25 0.11 0.43 -0.75 4.36 3.90 2kvaA11 GLN 707 HB2 -0.58 -0.18 0.20 -0.04 2.15 1.55 2kvaA11 GLN 707 HB3 -0.28 0.02 0.03 -0.04 2.02 1.75 2kvaA11 GLN 707 HG2 -0.26 0.28 0.05 -0.04 2.40 2.43 2kvaA11 GLN 707 HG3 -0.18 -0.04 0.05 -0.04 2.39 2.17 2kvaA11 GLN 707 HE21 -0.04 0.01 -0.06 -0.04 6.97 6.84 2kvaA11 GLN 707 HE22 -0.07 -0.02 -0.07 -0.04 7.69 7.49 2kvaA11 GLU 708 H -1.03 -0.04 -0.09 -0.55 8.60 6.90 2kvaA11 GLU 708 HA -0.17 0.18 0.49 -0.75 4.29 4.04 2kvaA11 GLU 708 HB2 -0.14 0.15 -0.13 -0.04 2.09 1.94 2kvaA11 GLU 708 HB3 -0.17 -0.16 0.02 -0.04 1.99 1.64 2kvaA11 GLU 708 HG2 -0.02 0.03 -0.22 -0.04 2.34 2.08 2kvaA11 GLU 708 HG3 -0.03 0.02 0.03 -0.04 2.34 2.32 2kvaA11 GLU 709 H -0.21 0.12 -0.07 -0.55 8.60 7.89 2kvaA11 GLU 709 HA 0.31 -0.02 0.39 -0.75 4.29 4.22 2kvaA11 GLU 709 HB2 0.09 -0.04 -0.06 -0.04 2.09 2.04 2kvaA11 GLU 709 HB3 0.12 0.08 0.01 -0.04 1.99 2.15 2kvaA11 GLU 709 HG2 0.45 -0.04 0.11 -0.04 2.34 2.83 2kvaA11 GLU 709 HG3 0.34 0.37 0.22 -0.04 2.34 3.22 2kvaA11 ASP 710 H -0.02 0.08 0.05 -0.55 8.40 7.96 2kvaA11 ASP 710 HA -0.07 0.29 0.91 -0.75 4.63 5.01 2kvaA11 ASP 710 HB2 -0.10 -0.02 0.19 -0.04 2.71 2.75 2kvaA11 ASP 710 HB3 -0.13 0.01 0.06 -0.04 2.70 2.60 2kvaA11 ASN 711 H -0.07 0.11 0.14 -0.55 8.53 8.16 2kvaA11 ASN 711 HA -0.01 0.19 0.43 -0.75 4.76 4.62 2kvaA11 ASN 711 HB2 -0.02 0.03 0.10 -0.04 2.88 2.95 2kvaA11 ASN 711 HB3 -0.03 -0.06 0.12 -0.04 2.79 2.79 2kvaA11 ASN 711 HD21 0.01 0.03 -0.02 -0.04 7.03 7.01 2kvaA11 ASN 711 HD22 -0.01 -0.03 -0.02 -0.04 7.74 7.63 2kvaA11 SER 712 H -0.13 -0.18 -0.08 -0.55 8.46 7.52 2kvaA11 SER 712 HA 0.14 0.20 0.64 -0.75 4.49 4.71 2kvaA11 SER 712 HB2 -0.12 -0.02 0.02 -0.04 3.95 3.80 2kvaA11 SER 712 HB3 -0.06 0.20 -0.26 -0.04 3.93 3.78 2kvaA11 THR 713 H -0.10 -0.11 0.05 -0.55 8.28 7.58 2kvaA11 THR 713 HA 0.09 0.48 1.14 -0.75 4.39 5.35 2kvaA11 THR 713 HB -0.03 -0.07 0.20 -0.04 4.32 4.38 2kvaA11 THR 713 HG23 0.04 0.03 -0.15 -0.04 1.22 1.09 2kvaA11 TYR 714 H 0.35 0.57 0.07 -0.55 8.29 8.72 2kvaA11 TYR 714 HA 0.16 -0.10 0.42 -0.75 4.56 4.28 2kvaA11 TYR 714 HB2 0.21 0.07 0.14 -0.04 3.06 3.43 2kvaA11 TYR 714 HB3 0.01 0.01 -0.09 -0.04 2.98 2.86 2kvaA11 TYR 714 HD2 -0.44 0.12 -0.09 -0.04 7.15 6.69 2kvaA11 TYR 714 HE2 0.06 0.03 -0.10 -0.04 6.85 6.80 2kvaA11 ASN 715 H 0.03 0.04 0.31 -0.55 8.53 8.37 2kvaA11 ASN 715 HA 0.13 0.48 0.97 -0.75 4.76 5.58 2kvaA11 ASN 715 HB2 -0.03 0.03 0.11 -0.04 2.88 2.95 2kvaA11 ASN 715 HB3 -0.11 -0.13 0.15 -0.04 2.79 2.66 2kvaA11 ASN 715 HD21 0.02 -0.04 -0.02 -0.04 7.03 6.94 2kvaA11 ASN 715 HD22 0.07 0.37 0.21 -0.04 7.74 8.35 2kvaA11 PHE 716 H 0.27 0.50 0.36 -0.55 8.34 8.92 2kvaA11 PHE 716 HA 0.07 0.30 1.03 -0.75 4.62 5.27 2kvaA11 PHE 716 HB2 0.15 -0.04 -0.05 -0.04 3.15 3.17 2kvaA11 PHE 716 HB3 0.08 -0.01 -0.24 -0.04 3.06 2.85 2kvaA11 PHE 716 HD2 0.03 0.05 -0.58 -0.04 7.28 6.74 2kvaA11 PHE 716 HE2 -0.26 -0.00 -0.24 -0.04 7.38 6.84 2kvaA11 PHE 716 HZ -1.25 -0.02 -0.21 -0.04 7.32 5.80 2kvaA11 ARG 717 H 0.10 0.89 0.30 -0.55 8.46 9.20 2kvaA11 ARG 717 HA -0.04 0.24 1.07 -0.75 4.34 4.86 2kvaA11 ARG 717 HB2 0.07 0.03 0.22 -0.04 1.90 2.18 2kvaA11 ARG 717 HB3 -0.32 0.02 0.05 -0.04 1.80 1.50 2kvaA11 ARG 717 HG2 -0.03 0.02 -0.01 -0.04 1.67 1.60 2kvaA11 ARG 717 HG3 -0.01 -0.05 -0.11 -0.04 1.67 1.46 2kvaA11 ARG 717 HD2 0.20 0.00 -0.02 -0.04 3.22 3.37 2kvaA11 ARG 717 HD3 0.05 -0.03 -0.04 -0.04 3.22 3.17 2kvaA11 TRP 718 H 0.05 0.82 0.32 -0.55 7.97 8.60 2kvaA11 TRP 718 HA -0.19 0.34 0.81 -0.75 4.62 4.82 2kvaA11 TRP 718 HB2 -0.23 -0.08 -0.22 -0.04 3.23 2.66 2kvaA11 TRP 718 HB3 -0.38 0.01 -0.02 -0.04 3.23 2.80 2kvaA11 TRP 718 HD1 -0.52 -0.06 -0.61 -0.04 7.22 5.99 2kvaA11 TRP 718 HE1 -0.46 0.18 -0.09 -0.04 10.20 9.79 2kvaA11 TRP 718 HE3 -0.22 -0.07 -0.25 -0.04 7.59 7.01 2kvaA11 TRP 718 HZ2 -0.67 0.11 -0.13 -0.04 7.44 6.71 2kvaA11 TRP 718 HZ3 -0.27 -0.02 -0.32 -0.04 7.13 6.48 2kvaA11 TRP 718 HH2 -0.77 -0.09 -0.23 -0.04 7.19 6.06 2kvaA11 TYR 719 H 0.07 0.61 0.25 -0.55 8.29 8.68 2kvaA11 TYR 719 HA 0.15 0.25 1.09 -0.75 4.56 5.30 2kvaA11 TYR 719 HB2 0.07 -0.08 0.23 -0.04 3.06 3.25 2kvaA11 TYR 719 HB3 0.08 0.31 0.08 -0.04 2.98 3.41 2kvaA11 TYR 719 HD2 0.09 0.05 0.03 -0.04 7.15 7.28 2kvaA11 TYR 719 HE2 0.07 -0.04 -0.03 -0.04 6.85 6.82 2kvaA11 THR 720 H 0.22 0.81 0.33 -0.55 8.28 9.08 2kvaA11 THR 720 HA 0.22 0.09 0.76 -0.75 4.39 4.70 2kvaA11 THR 720 HB 0.44 0.03 -0.14 -0.04 4.32 4.60 2kvaA11 THR 720 HG23 0.02 -0.02 -0.13 -0.04 1.22 1.05 2kvaA11 SER 721 H 0.15 0.53 0.14 -0.55 8.46 8.74 2kvaA11 SER 721 HA 0.06 0.10 0.54 -0.75 4.49 4.45 2kvaA11 SER 721 HB2 0.02 -0.22 0.18 -0.04 3.95 3.89 2kvaA11 SER 721 HB3 -0.10 0.15 0.13 -0.04 3.93 4.06 2kvaA11 TYR 722 H 0.24 0.12 -0.18 -0.55 8.29 7.92 2kvaA11 TYR 722 HA -0.04 0.21 0.39 -0.75 4.56 4.37 2kvaA11 TYR 722 HB2 0.01 0.01 0.01 -0.04 3.06 3.05 2kvaA11 TYR 722 HB3 -0.12 0.01 0.05 -0.04 2.98 2.88 2kvaA11 TYR 722 HD2 0.05 0.08 0.09 -0.04 7.15 7.33 2kvaA11 TYR 722 HE2 0.07 -0.04 -0.05 -0.04 6.85 6.79 2kvaA11 ALA 723 H 0.09 0.20 -0.77 -0.55 8.40 7.37 2kvaA11 ALA 723 HA -0.18 0.07 0.46 -0.75 4.34 3.94 2kvaA11 ALA 723 HB3 0.16 0.02 -0.20 -0.04 1.41 1.34 2kvaA11 CYS 724 H 0.06 0.34 -0.47 -0.55 8.50 7.87 2kvaA11 CYS 724 HA 0.30 0.18 0.91 -0.75 4.58 5.22 2kvaA11 CYS 724 HB2 0.09 0.15 0.13 -0.04 2.97 3.30 2kvaA11 CYS 724 HB3 0.14 -0.07 0.03 -0.04 2.97 3.03 2kvaA11 PRO 725 HA 0.40 0.16 0.35 -0.51 4.44 4.84 2kvaA11 PRO 725 HB2 0.12 -0.01 0.08 -0.04 2.28 2.43 2kvaA11 PRO 725 HB3 0.02 0.05 0.08 -0.04 2.02 2.13 2kvaA11 PRO 725 HG2 0.27 0.02 0.06 -0.04 2.03 2.33 2kvaA11 PRO 725 HG3 0.44 0.06 0.00 -0.04 2.03 2.49 2kvaA11 PRO 725 HD2 0.23 0.06 0.14 -0.04 3.68 4.07 2kvaA11 PRO 725 HD3 0.44 0.20 0.15 -0.04 3.65 4.41